DIMENSIONAL DATA - ACCESSORIES / OPTIONS

Figure 11.1 

Model WCC - Duct Collars

Table 11.1 

 

 

Model WCC

100% Air Inlet or Outlet Duct Collars

A

C

D

3/4"

B

A

C

 Unit
 Size 

A  B  C  D E

 002

 18-1/4 4-1/4 10-3/8  2-1/2  3

 

003

 23-1/4 4-1/4 10-3/8  2-1/2  3

 

004

 28-1/4 4-1/4 10-3/8  2-1/2  3

 

006

 41-1/4 4-1/4 10-3/8  2-1/2  3

 

008

 44-1/4 4-1/4 10-7/8  2-1/2 5-1/4

 

010

 44-1/4 5-1/4 10-7/8  2-1/2 4-1/4

 

012

 58-1/4 4-1/4 12-7/8  2-1/2 5-1/4

 

014

 58-1/4 5-1/4 12-7/8  2-1/2 4-1/4

Figure 11.2

Model FC - Outside Air Duct Collar

Table 11.2 

 

 

Model FC 

25% and 100% Fresh Air Duct Collar

 All dimensions are in inches.   

 

 

➁ 

Includes 3/4" top and bottom duct flanges for duct connection.

 

Outside Air Percentage

 25%  100%

 

1, 3, or 6 

2, 4, or 5

 Unit Size 

B C  A B C

 002 

12 1/4  3 1/2 

13 1/4 

18 1/2  4 1/4 

10 1/8

 

003

 

12 1/4  3 1/2 

15 3/4 

23 1/2  4 1/4 

10 1/8

 

004

 

12 1/4  3 1/2 

18 1/4 

28 1/2  4 1/4 

10 1/8

 

006

 

12 1/4  3 1/2 

24 3/4 

41 1/2  4 1/4 

10 1/8

 

008

 

24 1/4  3 1/2 

23 3/4 

44 1/2  4 1/4 

13 5/8

 

010

 

24 1/4  3 1/2 

23 3/4 

44 1/2  5 1/4 

13 5/8

 

012

 

24 1/4  3 1/2 

29 3/4 

58 1/2  4 1/4 

12 5/8

 014 

24 1/4  3 1/2 

29 3/4 

58 1/2  5 1/4 

12 5/8

Nomen 

Digit 18

B

3/4"

E

E

C

A

C

3/4"

B

C

C

Figure 11.3

Model WCC - Permalap Frame

11

AIR11-500.6

Summary of Contents for Model FC series

Page 1: ...nsers are warranted for operation at hot water pressures up to 200 lbs per sq in gauge and or temperatures up to 240 F or steam pressures up to 10psig for one row coils only The 3 4 row condensers are...

Page 2: ...blanketed by their air streams 8 Mounting height is critical for optimum performance Refer to Mounting Height on page 4 before installation WARNING 1 Disconnect power supply before making wiring conn...

Page 3: ...ring must comply with CSA C22 1 Electrical Code 2 Electric wiring must be sized to carry the full load amp draw of the motor and any controls that are used with the unit heater Overcurrent protectors...

Page 4: ...unit heaters when operated with steam pressures other than 2 pounds or with water at other than entering temperature of 220 F 1 3 1 2 1 1 1 0 9 8 7 6 5 CORRECTION FACTOR R AVERAGE WATER TEMP F 150 160...

Page 5: ...Arrangement 98 Model CW Arrangement 97 Model CW Arrangement 96 Model CW Arrangement 90 Model CW Arrangement 00 Model CW Arrangement 06 Model CW Arrangement 07 Model CW Arrangement 58 Model CW Arrangem...

Page 6: ...r left or right side connection with left hand piping as factory standard Power Assembly STD Blower platform blower and blower motor on all sizes are removable as a single unit A direct drive multi sp...

Page 7: ...NPT 1 NPT 1 NPT 1 NPT Blowers Direct Drive No Dia x Width Inches 1 5 1 4 x 7 1 5 3 4 x 7 2 5 1 4 x 7 2 5 3 4 x 7 3 5 3 4 x 7 3 5 3 4 x 7 4 5 3 4 x 7 4 5 3 4 x 7 High Speed Rpm 1625 1625 1625 1625 1625...

Page 8: ...12 10 7 5 7 8 47 5 8 39 5 8 9 3 4 205 012 83 3 4 28 12 10 7 5 1 8 59 5 8 51 5 8 9 3 4 240 014 83 3 4 28 12 10 7 5 7 8 59 5 8 51 5 8 9 3 4 240 Unit Size Approx Unit Weight lbs Figure 8 1 Floor Model FC...

Page 9: ...3 4 240 014 83 3 4 28 12 5 7 8 59 5 8 9 3 4 240 Table 9 1 Cabinet Dimensions inches Table 9 2 Filter Dimensions inches Model Size Filter Size 002 8 1 2 x 20 3 4 x 1 2 003 8 1 2 x 25 3 4 x 1 2 004 8 1...

Page 10: ...COIL CONNECTION DIMENSIONS 3 4 ROW COIL UNITS Table 10 1 10...

Page 11: ...Duct Collar Table 11 2 Model FC 25 and 100 Fresh Air Duct Collar All dimensions are in inches Includes 3 4 top and bottom duct flanges for duct connection Outside Air Percentage 25 100 1 3 or 6 2 4 o...

Page 12: ...cleaned frequently Do not use any commercial solvent that could deteriate the coil and do not use any liquid or steam sprays that could damage electrical components Good filter maintenance will minimi...

Page 13: ...SHIPMENT FROM SELLER These warranties are issued only to the original owner user and cannot be transferred or assigned No provision is made in these warranties for any labor allowance or field labor p...