11
FH-W1802
7. MAKING THE ELECTRICAL CONNECTIONS (cont.)
FIGURE 10
Receiver to house supply wires electrical connections: (Fig. 9 &10)
1. Lift motor assembly and hang it on the hook of mounting bracket
using one of the screw holes. (Fig. 9)
2. Secure the safety cable to the building structure using a wood
screw (not included). (Fig. 9)
3. Connect the fan assembly ground wire, mounting bracket ground
wire and receiver ground wire to the ground wire in outlet box.
(Fig.
10)
WARNING: Failure to connect ground wires could result in poor
fan control functionality .
4. Connect the black (hot) wire from the ceiling to the black wire
marked “AC in L” from the receiver. (Fig. 10)
5. Connect the white (neutral) from the ceiling to the white wire
marked “AC in N” from the receiver. (Fig. 10)
Receiver
FIGURE 9
White (“AC IN N”)
Black (“AC IN L”)
Black (hot)
Outlet Box
White (neutral)
Green (Ground)
Green (Ground) from
hanger ball
Green (Ground) from
receiver
Green (Ground) from
hanger bracket
Motor
Trim Ring
Safety Cable
Wood Screw