15. TROUBLESHOOTING
Problem
Solution
Fan will not start.
1.
Check circuit fuses or breakers.
2.
Check wall control LED indicator light. If LED is not illuminated when pushing a button, it is not
transmitting a signal. Please check power to wall control and all electrical connections.
3.
Assure that there are no more than 2 fans operating on a circuit through the wall control. Assure that there are no
more than 12 fans operating on a circuit through an on/off wall switch or a breaker (not through a wall control).
4.
Assure that the fan is within range of the Wifi (150 ft.) or wall control (30 ft.).
Fan sounds noisy.
1.
Allow a 24-hour “breaking-in” period. Most noise associated with a new fan will disappear
during this time.
2.
Make sure all motor housing screws are securely fastened.
3.
Make sure the screws that attach the fan blade to the fan are securely fastened.
4.
Make sure your ceiling box is secure and rubber isolator pads are used between the mounting bracket and outlet
box.
Fan wobbles.
1.
Check that all blade and blade arm screws are securely fastened.
2.
If the blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight
and possibly result in smoother operation.