9. MAKING THE ELECTRICAL CONNECTIONS (cont.)
Receiver
White (“AC IN N”)
Black (“AC IN L”)
Black (hot)
Outlet box
White (neutral)
Green (ground)
Green (ground)
from hanger ball
Green (ground)
from hanger ball
Green (ground)
from receiver
Receiver to house supply wires electrical connections:
(Fig. 11 & 12)
1.
Lift motor assembly and hang it using the cable/hook as shown in Figure
11.
2.
Secure the safety cable to the building structure using a wood screw (Fig.
11).
3.
Connect the fan assembly ground wire, mounting bracket ground wire
and receiver ground wire to the ground wire in outlet box (Fig. 12).
WARNING
: Failure to connect ground wires could result in poor fan
control functionality.
4.
Connect the white wire from the fan to the white wire marked “for light”
from the receiver.
5.
Connect the black wire from the fan to the blue wire marked “for light”
from the receiver.