2

 

 

INSTALLATION INSTRUCTIONS

540-Outdoor Wall Sconce

WS-W54016/WS-W54020/WS-W54025

 

FIG. 1

Fixture Wires

Black or 

Smooth

Fixture Wires

White or 

Ribbed

Fixture Wires

Bare wire

(Ground)

House Wires

Black

(Hot)

House Wires

White 

(Neutral)

House Wires

Green or Bare Copper

(Ground)

FIG. 2 Wiring

Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.    Nov. 2019

modernforms.com

Phone (800) 526.2588
Fax       (800) 526.2585

Headquarters/Eastern Distribution Center

44 Harbor Park Drive  
Port Washington, NY 11050

Central Distribution Center

1600 Distribution Ct
Lithia Springs, GA 30122

Western Distribution Center  

1750 Archibald Avenue  
Ontario, CA 91760

PREPARATION

1.     Shut off the power at the circuit breaker and 
        remove existing fixture, including the crossbar.
2.     Carefully unpack your new fixture and lay out 
        all the parts on a clear area. Be careful not to 
        lose any small parts necessary for installation. 

MOUNTING THE FIXTURE (Fig. 1)

3.     Remove the mounting screw (B) and rubber 
        gasket (C) from the mounting backplate.
4.     Secure the mounting back plate to the junction 
        box using standard junction box screws that 
        comes with the junction box.(For model 
        WS-W54016 and WS-W42020, drill holes in the 
        wall aligned with the key holes in the mounting 
        backplate, insert the plastic anchors (E),fasten
        the mounting backplate to the wall using wood 
        screw (D).
  

        Note:  

(i) using any other non-original-manufacturer provided junction box screw may result in safty issue;

 

  (ii) The side of the mounting plate marked “GND” must face out.

CONNECTING THE WIRES (Fig. 2)

5.     Connect the fixture’s wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has  
        a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back  
        plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

COMPLETING THE INSTALLATION 

6.     Secure the fixture to the mounting back plate using the mounting screw (B) 
        and rubber gasket (C).
7.     Insert the glass into the lamp cap, then push the glass up to the spring until
        the glass is fully positioned within the fixture. Release the glass gently to  
        prevent any external damages from all the tensional spring and make slight
        adjustment to allow the glass properly aligned with the fixture body.
8.     To prevent moisture from entering the outlet box and causing a short, use 
        clear caulking (i.e. indoor/outdoor silicone sealant) to outline the outside 
        of fixture back plate where it meets the wall. Leave a space at the bottom to 
        allow moisture to escape Fig.3

Limit 

Block

Tension

Springs

Clear Hammered

Seedy Glass

(RPL-GLA-54016)

(RPL-GLA-54020)

(RPL-GLA-54025)

Rubber Gasket

C

Mounting Screw

B

Wood

 Screw

Junction Box Screw

Mounting Backplate

Plastic Anchor

E

Junction Box

Wire Connector

A

D

Black Wire

White

 Wire

Ground

 Wire

Lamp Cap

Push

Release

Mounting Plate Dimensions

WS-W54016  4 1/8"
WS-W54020  4 1/4"
WS-W54025  4 1/2"

WS-W54016   7 5/8"

WS-W54020  9 1/2"

  WS-W54025  11 7/8"

1 3/4"

1 3/8"

Caulking

Junction Box

FIG.3 Sealing