2. General description of the product 

 

a. Technical specification 

Model: 

GLOBE VALVES 

Port: 

Standrad Port 

End connection: 

Flanged End 

Service fluid 

Dangerous or non-dangerous gas or liquid 

Service temp. 

-20°C  to  180°C 

Nominal Size NPS 

½” ¾’’ 1’’ 1¼’’ 

1½”

2’’ 2½”

3’’ 4’’ 5’’ 6’’ 8’’ 10’’

12’’

Nominal Size DN 

15 20 25 32 40 50 65 80 100

125 

150 200

250

300

Nominal pressure PN 

16 16 16 16 16 16 16 16 16 16 16 16 16 16 

Shell Material 

1.4408/EN1503-1,1.0619/EN1503-1 

Note 1: User shall consider the material’s anti-corrosion feature of components which directly 

contact with the fluid. The corrosion data information is available in this user manual. 

 

b. Safety features 

  Appropriate shell strength     

  Anti-blow out stem design 

 Anti-static design 

  Pressure release hole at ball 

  Pressure release channel at ball seat

 

c.  Dimensions and Parts list 

See the following drawing for the detailed 
external dimensions of each nominal size, 
the components list and materials available. 
User shall consider the material’s 
anti-corrosion feature of seals and packing 
which directly contact with the fluid. The 
corrosion data information is available in this 
user manual.

 

d. Equipment category according to ATEX 

Directive (94/9/EC)

 

Designed and constructed to good 
engineering practice and the ignition hazard 
assessment ensure that the equipment does 
not contain any effective ignition sources in 
normal operation and during expected 
malfunctions. Therefore we classified as 

Group II, Category 2

 equipment. The Type 

of ignition protection is ‘c’, constructional 
safety according to EN 13463-5:2003. 

 

 

e. Equipment category according to PED 

Directive (97/23/EC) 

 

Nominal 

Pressure

Category I CategoryII 

PN16 

DN15 
DN20 
DN25 
DN32 

DN40 
DN50 
DN65 
DN80 

DN100 
DN125 
DN150 
DN200 
DN250 
DN300 

 

Summary of Contents for GLOBE Series

Page 1: ...ut prior notice Flanged Globe Valves S S API 603 DIN PN16 USER MANUAL Modentic Industrial Corporation 14F 1 No 57Taya Rd Taichung Taiwan R O C Email modentic ms9 hinet net http www modentic com tw WARRANTY Modentic warrants its products against defects in manufacturing if the products Are used for the purposes for which they are manufactured and sold This warranty Shall expire one year from date o...

Page 2: ...Temperature Ratings 4 Delivery Condition and Storage 5 Installation and Operation 6 Put into service 7 Dangers of inappropriate use 8 Maintenance 9 Corrosion Data 10 Use in potential explosive atmosphere areas 11 Marking Importer Agent or Distributor responsible for servicing ...

Page 3: ...ual application The allowable temperature is between 20 C and 180 C Do not exceed the temperature range to avoid danger d Liquids with high fluid velocity When valves must be operated frequently on liquids with very high velocity a Globe shall be made with the valve distributor or manufacturer for appropriate advice to minimize the possibility of seat deformation especially when they are highly pr...

Page 4: ...annel at ball seat c Dimensions and Parts list See the following drawing for the detailed external dimensions of each nominal size the components list and materials available User shall consider the material s anti corrosion feature of seals and packing which directly contact with the fluid The corrosion data information is available in this user manual d Equipment category according to ATEX Direc...

Page 5: ...3 f Dimensions Parts List ...

Page 6: ...nvironment operator must Globe is there any foreign body or dusts inside the bore If yes clean it before installation Operator clean the valves by water compression air or steam automation valve shall be cleaned only with water or steam the compression air is not allowed 5 2 Thread cutting Care should be taken not to thread cut the pipes excessively Care should be taken not to over tighten the pip...

Page 7: ...ch as pressure temperature and fluid b If the product has any inappropriate use the product was damage however there are no signals occurs immediately User shall change the product to avoid danger in the future 8 Maintenance a Maintenance frequency The maintenance frequency is determined upon the application User shall consider the time interval depend on the kinds of fluid flow velocity operation...

Page 8: ...as some parts in an correct position or interference please dismantle and re assembly Otherwise the valve will get damaged easily when working on pipeline under higher pressure e Assembly For assembly process it takes the opposite way of dismantle process The must in the close position during assembling the body and end cap the stopper must be located at the right place otherwise the open and clos...

Page 9: ... equipment e The internal parts such as seals and packing can be adversely affected by some solvents List of solvents which are known to be compatible with the seal and packing material are provided in the corrosion data information f The equipment also conforms to Pressure Equipment Directive 97 23 EC The mechanical strength of the structure can withstand the hazard cause by internal pressure 11 ...

Reviews: