Electric installation
:
1.
The supply voltage should correspond with the working voltage of the appliance.
2.
The fixed arrangement of wire should be equipped with a all-poles disconnecting switch whose
poles have a contact separation at a minimum clearance of 3mm. Grounding leakage protection
switch is recommended. Do not put any sundries in front of the switch for convenient operation
sake.
3.
There is an earth stud at rear of the furnace body, which should be connected with a copper wire
that no less than 1.5mm
2
and ground wire that complying with safety regulations reliably.
Notice:
1.
Check the connection, voltage and safety grounding after installation.
2.
The appliance should be placed in a smooth area and kept a minimum clearance of 10cm away
from the incombustible object on both sides and 20cm at the back (e.g. walls, windows etc.).
3.
The mounting position should keep away from the flammable and explosive objects. The ambient
temperature should below 45
℃
and the relative humidity should below 85
%
.
4.
Installation should be operated by professional technician.