7
more that 7°C, then restart.
The appliance does not work
(ICE FULL and FAULT lights
flash simultaneously)
ICE FULL sensor is damaged or not
connected.
Contact MODENA Call Center to
replace the sensor.
The appliance does not work
(FAULT light illuminates)
Condenser sensor is damaged or not
connected.
Contact MODENA Call Center to
replace the sensor.
WATER LOW and ICE FULL
illumate simultaneously or the
FAULT illuminate rapidly.
1. Refrigerant leaked.
2. Compressor does not run.
3. Ambient temperature is below
6°C.
1. Contact MODENA Call Center.
2. Make
sure
the
ambient
temperature is below 43°C,
then restart. If the appliance
still does not work, contact
MODENA call Center.
3. Keep the ambient temperature
over 7°C.
FAULT,
WATER
LOW,
ICE
FULL lights illuminate slowly.
1. The sensor is not in correct
position or damaged.
2. Motor is damaged.
1. Contact MODENA Call Center
to adjust or replace it.
2. Contact MODENA Call Center
to adjust or replace it.
Only the FAULT light illuminates
rapidly (after working a period).
1. Ice motor is damaged.
2. Micro-switches do not function.
3. Water box broken.
4. Water box was blocked by ice
cubes.
1. Contact MODENA Call Center
to adjust or replace it.
2. Contact MODENA Call Center
to adjust or replace it.
3. Contact MODENA Call Center
to adjust or replace it.
4. Remove the ice cubes.
The appliance stops after 2
minutes or more (the WATER
LOW light flashes)
1. No water supply.
2. Water inlet valve is damaged or
not connect.
3. Water level sensor is not in
correct position.
1. Check the water supply.
2. Check the water outlet pipe or
replace it.
3. Adjust the water level sensor,
contact MODENA Call Center.
WATER
LOW
light
always
illuminates.
No water supply for more than 24
hhours/
Stop the appliance and restart
when the water supplied.
Ice cubes stuck in the water box.
1. The electric valve does not
function.
2. Some ice remain in the water
box.
1. Contact MODENA Call Center
to checl the valve electrical
connecting or replace it.
2. Stop the appliance and move
the ice.
The appliance does not work
without any error.
1. The electric valve leaks.
2. Compressor does not run.
1. Contact MODENA Call Center
to replace.
2. Contact MODENA Call Center
to replace.
Ice cubes forms different.
The refrigerant leaks.
Contact MODENA Call Center to