English
30
4.2.3 Detailed description of functions
4.2.3.1 Heating/Heat preservation function
The system could judge heating/heat preservation state and light up the corresponding indicator
based on the difference between actual temperature and setting temperature. If the water heater is in
heating state, indicator “HEATING” lights up (bright green); indicator “READY” lights up (bright red)
when in heat preservation state.
The water heater could be directly heated to the setting temperature after just starting or readjusting
the setting temperature. When the setting temperature is reached, it will stop heating and enter into
the heat preservation state. If the difference between actual temperature and setting temperature is
greater than the temperature return difference, water will be heated again.
4.2.3.2 Booking bath function
When in power-
on state, press “BOOK” key (
), then the booking indicator will light up. The system
will enter into booked time adjustment state and the digital tube flickers. At this moment, the user
could adjust the booked time through pressing “+” or “-” key.
4.2.3.3 Delay booking
This model adopts delay booking. That is, hot water is available after “XX” hours.
When in booking state, the user can not only adjust the booked time circularly in the range of “01-
02…-24-01” by clicking “+” key, but also adjust the booking hours circularly in the range of “24-23…-
01-
24” by clicking “-” key.
If “ADJUST” key is long pressed (or “+” or“-” key on remote controller ), the time can be adjusted at a
rate of 5 times per second. The operation chart of booking function is shown in Diagram 14.
Notes:
1.
The delay booking can’t set the minutes of the booked time;
2. In the setting process of booked time, booked time shall flicker. In the flickering period:
a. No key is pressed within 5s, then confirm the booking state;
b. Press
“BOOK” key, then confirm the booking mode immediately;
When in booking state, setting temperature can be adjusted.
However, heating and return
difference heating function can be identified only in booking heating process (namely 1
hour). Besides, READY indicator only lights up in the period when the actual temperature
decreases by 5
o
C after booking heating is finished.
3. The setting temperature could be adjusted under the booking state;
4. Booking for one time is valid repeatedly;
5. The booking indicator is always on during the entire booking process. when In power-on state,
pressing “BOOK” key will cancel booking function;
6. Upon the completion of booking installment, system will preheat 1 hour ahead. For instance, if the
user books water usage 6 h later, system will start heating immediately after 5 h from the current
time.
Booking heating will also be conducted at the same time of tomorrow (24 hours later),
and the like. This process is valid for long time.
7. Power failure does not affect booking and this product has the clock memory function;
Remarks: The power source of clock module has automatic charging function. One time
charging can maintain power failure time for about 5 days. Booking time accuracy cannot
be ensured, if exceeding that period.
Summary of Contents for ES 10D
Page 2: ......
Page 8: ...Bahasa Indonesia 6 2 4 Diagram Listrik Diagram 6 ...
Page 22: ......
Page 27: ...English 24 2 3 Brief introduction of product structure Note All dimensions are in mm ...
Page 28: ...English 25 2 4 Internal Wire Diagram Diagram 6 ...
Page 42: ......
Page 43: ......
Page 44: ......