background image

 

 

3.  Replace  the  gas  control 

valve. 

The  pilot is on but the main burners 
cannot be ignited

 

1.  The  pressure  of  the  gas  conduit  is 

too low. 

2.  The 

main 

burner 

nozzle  is 

blocked. 

3.  The  gas valve  is malfunctioning. 

1.  Regulate  the  gas  relief 

valve. 

2.  Dredge  the  main  burner 

nozzle. 

3.  Replace  the  gas  control 

valve. 

There’s  tempering  sound  when  cut 
off the gas source

 

1.  The  nozzle  orifice  diameter  does 

not match with  the gas source. 

2.  The 

damper 

is 

regulated 

oversized. 

3.  The  gas  source  pressure  is  on  the 

low  side. 

4.  The  inflow  of  the  connecting  pipe 

is too low. 

1.  Regulate 

the 

nozzle 

diameter. 

2.  Adjust 

the 

damper 

to a appropriate  size. 

3.  Regulate  the relief  valve. 
4.  Increase  the  allowable 

inflow  volume. 

There’s  red  flame  and  black 
smoke

 

1.  The  nozzle  diameter  does  not 

match with the  gas source 

2.  The 

damper 

is 

regulated 

undersized 

3.  The  gas  in  the  gas  bottle  is  almost 

used up 

4.  The  gas  composition  fluctuation  is 

huge  during  gas peak. 

1.  Regulate 

the 

nozzle 

diameter 

2.  Adjust the damper 

to a appropriate  size 

3.  Change  the  gas source 
4.  Regulate 

the 

inflow 

volume 

to 

relative 

smaller 

position, 

and 

adjust  it  back  to  normal 
when  the  gas  peak  is 
over 

 

Mentioned  troubles  are  just  for  reference.  If  any  failure  occurs,  please  stop  using,  and  call  MODENA  Call  Center  or 

the  authorized  technicians  to  check  and  repair.  Safety  first!  Please  cut  off  the  electric  and  gas  source  before 
maintenance.

 

 
 
 
 
 
 

MODEL 

CT 7960G 

CT 7640G 

CT 7320G 

Type 

Burner  Gas top 

Burner  Gas top 

Burner  Gas top 

Numbers  of  burner 

6 Gas 

4 Gas 

2 Gas 

Gas safety device 

Yes 

Yes 

Yes 

Color 

Stainless 

Stainless 

Stainless 

Gas type 

LPG & NG 

LPG & NG 

LPG & NG 

Power  (kW/BTU) 

46.6/159000 

25.2/86000 

15.5/53000 

Product  Dimension 

 

 

 

Length  (mm) 

900 

600 

300 

Width (mm) 

770 

770 

770 

Height  (mm) 

(360+60) 

(360+60) 

(360+60) 

*Use  nozzle 1.45mm 

 

Specifications  of  this  appliance  may  change  without  notice  to  improve  the  quality  of  the product.  Pictures in this 
manual  are  schematic  and  may  not  match  your  product  exactly.  Values  stated  on  the  machine  labels  or  in  the 
documentation  accompanying  it  are  obtained  in  laboratory  in  accordance  with  the  relevant  standards. 
Depending  on  operational  and  environmental  conditions  of  the appliance,  values  may  vary.

 
 

Part 6: Specification 

Summary of Contents for CT 7320G

Page 1: ...User Manual Book Burner CT 7960G CT7640G CT7320G CT 7660G ...

Page 2: ...m to deliver stylishly designed products equipped with state of the art technology to assist you in your daily activities This is your guidebook containing everything you need to know about our product Please reach out to us if you need further assistance or other information via our Customer Care or our official website www modena com ...

Page 3: ...3 CONTENTS Page INTRODUCTION 2 Part 1 Name of Parts 4 Part 2 Installation 6 Part 3 How to Use 7 Part 4 Cleaning Maintenance 8 Part 5 Troubleshooting 8 Part 6 Specification 9 ...

Page 4: ...4 Part 1 Name of Parts ...

Page 5: ...5 CT 7640G CT 7660G The picture is a general overview and is not necessarily the same as the product you receive Feautures and completeness depends on the type of products ...

Page 6: ... the device shall be connected by metal pipe 5 If the conduit pressure is higher or lower than the required pressure of the device of 10 there shall install a regulator to ensure the rated pressure 6 After connecting test the tightness of the joint with a solution of water and soap or detecting instrument Do not check it with open flame Special note 1 The installation initial start up and maintena...

Page 7: ...exhaust facilities to ensure that the steam and burned gases can be discharged during operation The device is only applicable to low pressure gas regulation valve otherwise it may cause property damages or personal injuries Dry heating of the appliance is prohibited Fire warning should any gas smell come prohibit any possible ignition of fire source Do not light the appliance or turn on electronic...

Page 8: ...een diluted Besides wipe it according to the direction of the satin weave 5 Do not modify the necessary air volume for combustion 6 After cleaning please clean up the liquid or dirt in the fire outlet with thin wire to eliminate the insecurity factors which may cause incomplete combustion or impede the spread of flame 7 Anytime when stop using it the gas supply shall be cut off 8 If the device is ...

Page 9: ... Change the gas source 4 Regulate the inflow volume to a relative smaller position and adjust it back to normal when the gas peak is over Mentioned troubles are just for reference If any failure occurs please stop using and call MODENA Call Center or the authorized technicians to check and repair Safety first Please cut off the electric and gas source before maintenance MODEL CT 7960G CT 7640G CT ...

Page 10: ...11 20 ...

Reviews: