6
CEILING MOUNTING INSTALLATION (ISLAND TYPE)
Attention! Observe the warning in the instruction sheet concerning the operation of the appliance when air is discharged
from the room.
1. For ceiling mounting installation, the ceiling must be strong and able to
hold the weight of at least 40 kg and the thickness of the ceiling must be
at least 30 cm. Position the hanging plate on the ceiling and then mark
the position of the screw holes.
The hanging plate should be securely fixed to the ceiling.
a)
11 x ST6 (40 mm) Screws for wooden ceiling.
b)
8 x expansion bolts for cement ceiling
2. Make the 17 cm hole for extensible pipeline if the system will use a
suction hood ducting / exhaust. Punch a hole through all the markings
on the template by using a drill with a diameter of 8 mm. Then put the
plate holder with dynabolt and fischer. Insert 4 pieces of angle iron on
the plate holder with 8 pieces of M5 screws and bolts, then connect the
other 4 pieces of angle iron with 16 pieces of M5 screws and bolts and
set the length of the connection brackets according to the distance to
the cooker hood suction (connection between brackets should not be
less than 100 mm
3. Attach the extensible pipe to the hole if the suction hood will be used with
the system ducting / exhaust.
4. Install the chimney above the plate holder with 4 screws, then funnel
down close to the top and attach a hook to hold temporarily.
5. Replace the glass panel (for certain types) with 4 pieces of bolts and rubber
rings and adjust its position appropriately
6. Lift the main body of the cooker hood onto the angle bar and then fix it
into position using the 16 pieces of M5 screws