Identification of the Dry-heating Problem
If the system detects the rising of inner container temperature that
is in ≥ 15
o
C /min or ≥ 8
o
C/30s, and the temperature is greater than
50
o
C, the error code E2 will be shown on display screen with
blinking display.
Identification of the Over-temperature Problem
If the temperature in the thermostat of the inner container is
greater than 90
o
C, over-temperature is identified and the error
code E3 is shown on display screen with blinking display.
Identification of the Sensor Problem
If the sensor turns off or the short circuit occurs, an alarm will beep
and the error code E4 will be shown on display screen with blinking
display.
NOTE
E2: Dry Heating--- Refill the appliance with water and re-heat.
E3: Overheating---Check the heating system or replace it.
E4: Sensor Error---Check the sensor or replace it.
.