![Modena Casella Series User Manual Book Download Page 26](http://html1.mh-extra.com/html/modena/casella-series/casella-series_user-manual-book_1817615026.webp)
26
Identification of the Over-temperature Problem
If the temperature of the thermostat of the inner container is
greater than 90
o
C, that case will be identified as over-temperature
problem; and the error code E3 will be shown on display screen
with blinking display.
Identification of the Sensor Problem
If the sensor turns off or the short circuit occurs, an alarm will beep
and the error code E4 is shown on display screen with blinking
display.
Other Technical Requirements
1. The overall dimension and the installation dimension of the
control panel and the power panel; height of components and
parts; the signal line between each other; and so on are in the
conformity with the corresponding pictures. Besides, the
control panel and power panel shall have good
interchangeability during matching. All the circuit board
materials adopt 1.6 mm thick anti-flaming epoxy board with
damp proof treatment. A complete set of the controller shall
be subject to ageing treatment before leaving the factory.
2. When the PCB board is laid out, creepage distance shall be
guaranteed to reach the corresponding standard. Thus, cords
are not allowed to be installed within 3 mm from the drilled
hole location.
NOTE
E2: Dry Heating--- Refill the appliance with water and re-heat.
E3: Overheating---Check the heating system or replace it.
E4: Sensor Error---Check the sensor or replace it.
.