b. 

Fixing the actuator on to the torque management device and/or on an adaptor 

 

To ensure the operator is working safely and in optimum conditions, it is imperative to use a torque retention system.  
Our actuators are delivered with:  

 

A BR001 torque management reaction bar 

 

A strap or a chain 

 

2 carabiners 

In addition to this basic pack, 

modec

 also has a wide range of torque management accessories (see the catalogue and the 

following presentation for more details).  

As well as these standard accessories, 

modec

 develops specific systems. If you would like to check your installation or if you 

have a specific solution request, contact a registered 

modec

 distributor. 

The 

modec

 standard flange and shaft can also accommodate some specific drive heads like the Banjo heads (for handwheels 

with  a  rising  stem,  or  simply  in  order  to  increase  the  torque)  or  a  right  angle  head  (for  a  better  operator  position  during 
operation). These heads also have a torque reaction system (torque retention arm, strap and carabiners). 

If  this  standard  equipment  does  not  provide  a 
torque  retention  that  offers  sufficient  safety  for 
both  operators  and  equipment, 

modec

  can 

develop and/or adapt special torque management 
systems.  

 

 

 

 

 

 

 

 

 

 

 

Never  use  a  portable  actuator  with  a  torque  management  system  that  is  under-sized,  unstable  or  badly 
positioned  
 

c. 

Fixing the BR001 torque management arm and anchoring strap 

 

Pull each fixation spring with the ring and rotate for a quarter turn so that they stay in the pulled position. 

Place the black ring of the torque management bar on the flange so that the 6 pins enter the corresponding holes. 

Make a quarter turn with the fixation springs rings and release the springs making sure they come back. 

Check that the torque management bar is properly secured to the flange. 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
 
 
 

Fixation 
spring 

 

6 pins

 

 

Actuator flange

 

 

Splined shaft 

Ø25x36 mm 

 

Fixation 
spring 

 

Summary of Contents for JA73

Page 1: ...is able to deliver a high power for more than one hour continuously It does not depend on any energy source electric plug or compressed air network and can operate freely anywhere Much more powerful...

Page 2: ...11 a General info 11 b Accuracy 12 c Use with a Banjo head 12 6 Setting up the Portable Valve Actuator 12 a General info 12 b Fixing the actuator on to the torque management device and or on an adapt...

Page 3: ...ice Updates will be available on our website www modec fr It is important to refer to the website before setting up or using the actuator and before carrying out maintenance Any modifications made to...

Page 4: ...gy clothes or jewelry It is obligatory to tie back hair and to wear close fitting clothes not floaty to ensure all clothing parts are distanced when moving To avoid the motor starting at the wrong tim...

Page 5: ...ort of dangerous materials The operator can transport the batteries by road without taking any additional measures o When transporting via a third party for example by air or a via a transport company...

Page 6: ...Duty XXXXXXXX Petrol gas PY68E xxx xx Gas Portable Actuator Easy Duty XXXXXXXX PY68S xxx xx Gas Portable Actuator Standard Duty XXXXXXXX PY68H xxx xx Gas Portable Actuator Heavy Duty XXXXXXXX Electri...

Page 7: ...cumbent on the company using the equipment to ensure that safety rules are respected Hearing protection Protective goggles Safety shoes Safety gloves level 3121 according to EN388 Safety signs Summary...

Page 8: ...speed 9 Control screen 10 Digital revolution counter option it gives a double reading rotation speed and number of turns General specifications JA73E S H Weight kg not including options and accessori...

Page 9: ...e equipment to which the tool is applied The end operator should establish the actual measurements Maximum level of weighted acoustic pressure A at the operator s location L pA 85 dB A Value of vibrat...

Page 10: ...the screen 3 Unlocking the actuator To unlock the actuator press the safety trigger 2 and click on the throttle button 3 Once the actuator is unlocked the Home screen displays the following informati...

Page 11: ...dication 1 to 4 triangles 7 Advanced information s available You can access the menu when the motor is idle only Each press on the Power button 1 changes the menu with the following path Rotation dire...

Page 12: ...to 300 for high speed and low torque settings It is thus necessary in order to improve the torque limit accuracy to slow the actuator when coming close to the limit required c Use with a Banjo head Wi...

Page 13: ...r simply in order to increase the torque or a right angle head for a better operator position during operation These heads also have a torque reaction system torque retention arm strap and carabiners...

Page 14: ...90 Handwheel rotation direction D1 CW Position of the strap chain 90 The chain must remain in the plane of the reaction bar and must not work at an angle greater than 30 to the perpendicular of the ba...

Page 15: ...ble BAT 1500 6 connection cable JA73 BAT 750 1200 1500 BAT 1500 4 connection cable BAT 1500 6 connection cable 4 Press the battery switch on I 5 Switch on the actuators The smart handle screen identif...

Page 16: ...m turn the valve in both directions several times to clean it modec revolution counter optional enables you to always know which position the valve is in 4 When the closed position is reached make sur...

Page 17: ...OW IT WORKS Revolution count mode t Speed mode s 3 s Reset to zero REVOLUTION COUNTER PARAMETERS The revolution counter is set by default for a straight or right angle head standard output shaft STD w...

Page 18: ...regulatory provisions that apply and any local workplace safety instructions including conditions relating to the work environment clothing and the operator s individual protective equipment as requi...

Page 19: ...down for at least 15 minutes User Motor card temperature 95 c Power limited Leave the Actuator to cool down for at least 25 minutes Motor card temperature 100 c Motor security activate modec Distribu...

Page 20: ...s and if payment or acceptance of bill is not performed on the agreed date even further to partial order performance may entail revision of the conditions thereof and the overall credit conditions gra...

Reviews: