background image

Continuity Tests

-

+

1

2

3

1

2

3

INPUT JACK

OUTPUT JACK

1

5

M

P

S

A

1

8

4

.7

K

2

M

B

E

C

OUTPUT

POT

DISTORTION

POT

1

0

4

J

10

4J

1

2

3

4

5

6

7

8

9

820

BLK

RED

+

-

GND

Guitar cable must be 
plugged into the input 
jack while taking voltage 
measurements

3PDT Foot Switch

1

2

3

4

5

6

7

8

9

Switching function of the 3PDT switch.  The solid line 

illustrates an internal connection between terminals.

1

2

3

4

5

6

7

8

9

With your meter set to check continuity, 
check the 

footswitch terminal continuity

 to 

make sure it is switching correctly.

The effect is 

on 

when there is continuity from 

terminals:

1 to 2, 4 to 5 and 7 to 8

The effect is 

bypassed

 when there is continuity from 

terminals:

2 to 3, 5 to 6 and 8 to 9

With the footswitch set to effect-on terminal 
continuity (as shown above), check for 

ground continuity

 to make sure you have 

proper ground connections between the 
output jack’s ground terminal (GND) and the 
following test points.

1. Terminal Strip Terminal #1 and GND

1

2. Transistor Emitter lead and GND

2

3. LED Cathode (-) lead and GND

4

4. Footswitch Terminal #5 and GND

3

5

5. Input Jack ground lug and GND

Reviews: