(1) Remove the dome
Take a cotton cloth and remove the transpar-
ent dome by turning it in
counter-clockwise
direction
.
(2) Insert the lens units and mount the central
lens screw
Remove the center lock screw and the
washer. Insert the lens units into the seatings.
Insert the lock screw with a washer into the
center of the camera and gently tighten it to
hold the lens units in place.
Caution:
Avoid over-tightening the screw as
this might damage the camera housing.
(3) Connect the ribbon cables to the lens units
Connect the ribbon cables marked
L
and
R
according to the
Image Sensor Combination
table (opposite page) to the installed lens
units.
Example:
A
D12D-Night
always
takes the
L
ribbon cable on the
(BW) lens mount, the
R
ribbon cable is
always
connected to the
(color) lens mount (see
Image Sensor Combi-
nation table on the opposite page).
While doing so, make sure that the
lens unit's ribbon cable connectors are
always pointing upwards into the dome
. This will ensure that the lenses
can be positioned freely later on, without putting any strain on the ribbon ca-
bles. Make sure that the ribbon cables are running properly along the inside
of the dome's rim. The ribbon cables must not obstruct the line of vision of
the lenses!
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
43
/124
D12 Camera Manual Part 1
Dismount the dome by
turning it
counter-clock-
wise