Zeus80 

                                                           User Manual 

V 1.1.2 - 21/10/2020 

          Page 15 of 16 

4  Technical data 

 

Power Supply                               12V 
Operating temperature 

 

-20°C / +40°C 

Dimensions and weight 

 

Generator: 490x330x265 mm. 24 Kg 

 

 

 

 

 

Cooling system: 370x175x260 mm. 4 Kg 

Battery types  

          

Free acid, Pb Seal, LiFePO4 

Fuel consumption   

 

From 0,2 to 0,4 lt/h 

Electrical consumption 

 

Max (45 sec during power on): up to 12A 

 
 

Standby: with display on: 120mA  

     with display off: 85mA  
     30 minutes after display switch off: 70mA 

Max operating height  

 

3000 mt above sea level 

 
Standard EMC

 

       ECE Regulation R10 rev. 5 + A1 

 

 

 

          

EN61000-6-1:2007 + EN61000-6-3:2007+A1:2011 

Standard ENV (Cold A) 

 

EN60068-2-1 

Standard acoustic tests 

 

EN ISO 3744 

Power supplied: 

 

 

80 W typical, see graphic below.  

 

 Note how the production of energy (vertical 
axis) varies according to the external 
temperature (horizontal axis). In addition, the 
system can be affected by other factors such as 
humidity, rarefaction of air due to altitude or 
atmospheric pressure and positioning of the 
cooling radiator. 
 

P.S.:

 data subject to change without notice and without changing functionality 

 
 

5  Warranty 

 

The  Zeus80  generator  is  covered  by  a  two-year  warranty,  which  can  be  extended  to  3  (three) 
years by registering the product on 

support.mobiltech.it

 

Warranty conditions are available on 

www.mobiltech.it

  

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ZEUS80 CD

Page 1: ...MANUAL ZEUS80 CD Power Supply Diesel Voltage 12V IMPORTANT You can obtain the 3 three year warranty extension by registering the product for free on support mobiltech it More information can be found...

Page 2: ...control 6 2 1 Main Menu Home 7 2 1 1 Service battery 8 2 2 Settings Menu 8 2 2 1 Mode Menu 9 2 2 2 Language Menu 9 2 2 3 Service Menu 10 2 2 4 Update Menu 11 2 2 5 Generator Menu 12 2 2 6 Reset Funct...

Page 3: ...in the vehicle s tank Use other than intended is not allowed During installation and normal operation the following instructions must be observed Installation must be performed by qualified personnel...

Page 4: ...tand by mode to reduce electrical consumption When switched on again it may take a few seconds to restore communication with all components The generator switches off automatically 3 minutes after the...

Page 5: ...al cases at external temperatures above 0 C the Zeus80 generator can also work with heating oil sec DIN 51603 from an additional tank If the Zeus80 generator is powered from a separate tank follow the...

Page 6: ...d into several menus In the figure below the menu structure is shown HOME SETTINGS MODE LANGUAGE SERVICE GENERATOR CONTROL UNIT Automatic Manual Italian English Spanish German French Dutch Combustion...

Page 7: ...duction Note Full Eco steps may take a few minutes due to the need to dissipate excess heat compared to the mode chosen It is therefore recommended to select the desired mode within the first 5 minute...

Page 8: ...en 2 2 Settings Menu The following figure shows the Settings menu Pressing the Home area returns to the system main screen Battery data Percentage of charge Back to Home Note the percentage of battery...

Page 9: ...urrent 3A For 3 min After 5 min Free acid Pb 12 2V For 3 min 14 8V or charge current 3A For 3 min After 5 min Lithium 12 8V For 1 min 14 2V or charge current 3A For 1 min After 1 min Mode Manual this...

Page 10: ...status of communications between the different components of the system C communication between the display unit and the power unit G communication between the power unit and the generator Both of th...

Page 11: ...ilable on the manufacturer site www mobiltech it The update is performed by inserting a memory card with the new software package into the MicroSD slot The instructions for programming the memory card...

Page 12: ...nal the error can be reset by pressing the relative icon for 3 5 seconds and waiting for another 5 10 seconds for the update and the checks performed by the system It is possible to reset errors by pr...

Page 13: ...ry temperature too high Place the service battery in a more ventilated place Display shows Too low battery Primary battery voltage too low The generator may not be able to turn on Charge the primary b...

Page 14: ...lant temperature too high Wait for the coolant temperature to drop Display shows Water outlet probe error Fault or lack of connection with outlet water probe Contact an authorized center for verificat...

Page 15: ...EN61000 6 1 2007 EN61000 6 3 2007 A1 2011 Standard ENV Cold A EN60068 2 1 Standard acoustic tests EN ISO 3744 Power supplied 80 W typical see graphic below Note how the production of energy vertical a...

Page 16: ...it Mail info mobiltech it service mobiltech it Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operat...

Reviews: