2.2.5  Generator Menu 

 

In this menu is possible to check the operating status of the generator components: 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

The icons shown in this figure can have on three different colors: 

-  Blue: working element actually active 
-  Gray: working element actually not active 
-  Red: failed element, error issued 

 
In  the  event  of  an  error  signal,  the  error  can  be  reset  by  pressing  the  relative  icon  for  3-5 
seconds and waiting for another 5-10 seconds for the update and the checks performed by the 
system. 
 
It is possible to reset errors by pressing the reset button (see following paragraph) 
 
 

2.2.6  Reset Function 

Use the reset button to reset the settings to the factory state. All errors will be cleared and the 
timers, mode and battery management will be reset. 
 
 
 
 
 
 
 
 
 
 

Back to  
Service Menu 

 

Combustion 
status 

 

Water pump 
status 

 

Fuel pump 
status 

 

Spark plug 
status 

 

Cooling fan 
status 

 

Burner fan 
status 

 

Reset Function 

 

Summary of Contents for ZEUS80 CD

Page 1: ...MANUAL ZEUS80 CD Power Supply Diesel Voltage 12V IMPORTANT You can obtain the 3 three year warranty extension by registering the product for free on support mobiltech it More information can be found...

Page 2: ...control 6 2 1 Main Menu Home 7 2 1 1 Service battery 8 2 2 Settings Menu 8 2 2 1 Mode Menu 9 2 2 2 Language Menu 9 2 2 3 Service Menu 10 2 2 4 Update Menu 11 2 2 5 Generator Menu 12 2 2 6 Reset Funct...

Page 3: ...in the vehicle s tank Use other than intended is not allowed During installation and normal operation the following instructions must be observed Installation must be performed by qualified personnel...

Page 4: ...tand by mode to reduce electrical consumption When switched on again it may take a few seconds to restore communication with all components The generator switches off automatically 3 minutes after the...

Page 5: ...al cases at external temperatures above 0 C the Zeus80 generator can also work with heating oil sec DIN 51603 from an additional tank If the Zeus80 generator is powered from a separate tank follow the...

Page 6: ...d into several menus In the figure below the menu structure is shown HOME SETTINGS MODE LANGUAGE SERVICE GENERATOR CONTROL UNIT Automatic Manual Italian English Spanish German French Dutch Combustion...

Page 7: ...duction Note Full Eco steps may take a few minutes due to the need to dissipate excess heat compared to the mode chosen It is therefore recommended to select the desired mode within the first 5 minute...

Page 8: ...en 2 2 Settings Menu The following figure shows the Settings menu Pressing the Home area returns to the system main screen Battery data Percentage of charge Back to Home Note the percentage of battery...

Page 9: ...urrent 3A For 3 min After 5 min Free acid Pb 12 2V For 3 min 14 8V or charge current 3A For 3 min After 5 min Lithium 12 8V For 1 min 14 2V or charge current 3A For 1 min After 1 min Mode Manual this...

Page 10: ...status of communications between the different components of the system C communication between the display unit and the power unit G communication between the power unit and the generator Both of th...

Page 11: ...ilable on the manufacturer site www mobiltech it The update is performed by inserting a memory card with the new software package into the MicroSD slot The instructions for programming the memory card...

Page 12: ...nal the error can be reset by pressing the relative icon for 3 5 seconds and waiting for another 5 10 seconds for the update and the checks performed by the system It is possible to reset errors by pr...

Page 13: ...ry temperature too high Place the service battery in a more ventilated place Display shows Too low battery Primary battery voltage too low The generator may not be able to turn on Charge the primary b...

Page 14: ...lant temperature too high Wait for the coolant temperature to drop Display shows Water outlet probe error Fault or lack of connection with outlet water probe Contact an authorized center for verificat...

Page 15: ...EN61000 6 1 2007 EN61000 6 3 2007 A1 2011 Standard ENV Cold A EN60068 2 1 Standard acoustic tests EN ISO 3744 Power supplied 80 W typical see graphic below Note how the production of energy vertical a...

Page 16: ...it Mail info mobiltech it service mobiltech it Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operat...

Reviews: