Add-on to an MA 1000 with MA 1200
MA 850 Installation and Configuration Guide
21
7. Connect the
MA 1000 antenna
ports
and the
MA 850 Mobile Services
ports using the
four SMA to N-type cables
supplied in the accessory kit
.
NOTE:
Be sure the connectors are closed at a 45 degree angle so as not to place stress on the cables.
Figure
3-3. Connection of MA 850 and MA 1000 Service Ports
8. Connect the
power.
It is recommended to use the following power supply for local power
configuration, where p
ower can also be supplied using remote power supply configurations
:
•
Dedicated power supply (i.e. LPS-48-100W which feeds both modules). Refer to the
Power Supplies Manual.
9. Connect the coax
antenna
cables to the MA 850 unit antenna ports on the MA 850 front
panel according to the following instructions:
•
Use 50 Ω, N-type male to male, 1/2” or 3/8” Plenum coax cables
•
Max cable length (typically): 150’
10. Fit 50 ohm terminators on all unconnected SMA, AP and antenna ports.
MA 1200
MA 850
MA 1000
Antennas
N-type SMA jumpers
(included)