TROUBLESHOOTING GUIDE:
TROUBLE RECOMMENDED SOLUTION
Vehicle does not start Make sure the Polarity Protection Green LED is illuminated. Turn the Main
Power Switch to ON Position to allow power into the booster clamps.
DO NOT turn the Main Power Switch to ON position if the Polarity
Protection RED LED is illuminated. Disconnect both booster clamps and
reconnect the Booster Clamps to the proper polarity.
Allow the QuickBoost to stay connected to the vehicle battery for a longer
period of time. Wait 6 to 8 minutes before attempting to start the vehicle
again.
Recharge the QuickBoost to a FULL charge status.
Replace the vehicle battery or visit workshop/garage for further
assistance.
12 Volt DC devices Recharge the QuickBoost to a FULL charge status.
connected to the 12 Volt
output port of the
Insert the device 12 Volt plug properly into the QuickBoost DC output port
QuickBoost
does not operate.
Internal Circuit Breaker is OFF. Remove the 12 Volt Accessory plug from
The BEAST 12VDC output port. Wait 15 - 25 minutes for automatic
Reset to regain power.
Compressor does not Recharge the QuickBoost internal battery to Full charge.
turn on.
Compressor does not inflate Make sure the hose nozzle is properly seated and the locking lever is in
down position.
Repair air hose if possible.
Allow 10 to 15 minutes for compressor to cool down before re-use.
USB powered device Press the USB output port SWITCH to ON position (
—
)
connected to the USB of
The QuickBoost doesn’t Insert the device USB plug properly into the QuickBoost USB port.
Function.
Model No. 2007
Sh
e
e
t
10
o
f 1
2