![Mobeye ThermoGuard TwinLog CML2285 User Manual Download Page 24](http://html1.mh-extra.com/html/mobeye/thermoguard-twinlog-cml2285/thermoguard-twinlog-cml2285_user-manual_1814845024.webp)
23
Example: to arm the system only during weekdays, from 6AM to 7PM, set the
TIMEARM1 to 06:00, TIMEDISARM1 to 19:00 and DAYS1 to 12345.
(Only) when using your own SIM card, the DATE and TIME must also be set
manually. The portal synchronizes this automatically.
5.17 BUTTONLOCK
It can be useful to lock the button to prevent the unit from being switched off
unintentionally. As default the buttonlock is locked (so, the button is disabled). To
disable the button, the buttonlock needs to be switched to "OFF.
5.18 ALARM INDICATION
The CML2285 has an internal piezo siren, which sounds at an alarm and keeps
sounding as long as the unit is in alarm status. The siren can be interrupted by
briefly pressing the button. The alarm indication can be disa
bled, so it won’t sound at
all (OFF). As default this indication is set t
o ‘ON’.
5.19 LOW POWER MODE
A battery-powered Mobeye CML2285 has the GSM module switched off in stand-by
mode. It only switches on if it has to send a message. An externally powered unit
always keeps the GSM module open (as factory default).
When using the “low power
mode” an externally powered unit will also keep the GSM module closed as much as
possible, to minimize the power consumption. To achieve this, the LOWPOWER
shall be set to "ON". In the low power mode, the presence of the external power
source will still be monitored.
5.20 PULSE TIME AND OUTPUT BEHAVIOUR
The output switches in the event of an alarm or after an incoming SMS command,
depending on the output behaviour. Output behaviour "ALARM" makes the output
Summary of Contents for ThermoGuard TwinLog CML2285
Page 1: ...USER MANUAL Mobeye ThermoGuard TwinLog CML2285 SW version 5 n...
Page 2: ......
Page 38: ...37...
Page 39: ...38...
Page 40: ......