![Mobeye ThermoGuard CM4200 User Manual Download Page 14](http://html1.mh-extra.com/html/mobeye/thermoguard-cm4200/thermoguard-cm4200_user-manual_1814842014.webp)
13
4.5
HOW TO ACTIVATE THE THERMOGUARD
After the previous steps the Mobeye ThermoGuard is ready for use. It is
armed automatically.
In order to switch off (disarm) the Mobeye
ThermoGuard:
- Press the button at the backside for 1 second. The
green LED switches off to indicate the disarmed
status.
In the disarmed status the Mobeye ThermoGuard
will not send alarm notifications. The unit remains
active and is able to switch on time-controlled and
to send test and 'low battery voltage' messages.
In order to switch on (arm) the Mobeye ThermoGuard:
- Press the button at the backside for 1 second. The green LED blinks once
every 3 seconds (battery-powered) or stays on continuously (in case of an
external power supply).
If powered externally (with network connection), switching can be done via
SMS commands:
SMS command to switch on:
CODE ARM
(e.g. 1111 ARM)
SMS command to switch off:
CODE DISARM
(e.g. 1111 DISARM)
To update the status in the Mobeye Internet Portal: press the button for 5
seconds, or - if the device is externally powered - send a question mark to
the unit (without code).
SMS command status update:
?
The
status
including
the
temperature value in the portal
will be refreshed (only possible
with external power).