Mobeye ThermoGuard CM4200 User Manual Download Page 1

 

 

 

 

 

 

USER MANUAL 

 

 

 

Mobeye

®

 ThermoGuard  

CM4200 

 

SW version 1.n

 

Summary of Contents for ThermoGuard CM4200

Page 1: ...USER MANUAL Mobeye ThermoGuard CM4200 SW version 1 n...

Page 2: ......

Page 3: ...4 5 Possible settings 15 5 1 Alarm phone numbers 15 5 2 Test message 15 5 3 minimum and or maximum temperature limit 16 5 4 Temperature delay time 16 5 5 Temperature calibration 16 5 6 Temperature uni...

Page 4: ...ended for use in dry and clean places Protect the device from moisture heat and water splashing Not intended for external use The guidelines for the battery usage must be regarded Do not expose the de...

Page 5: ...se of a network problem it will switch to another provider or fall back to 2G In addition the Mobeye SIM card offers access to the Mobeye Internet Portal This management environment gives the device e...

Page 6: ...used and a power failure occurs the Mobeye ThermoGuard sends a power failure message to Mobeye Internet Portal to be forwarded to the alarm contacts When the power is restored the Mobeye ThermoGuard...

Page 7: ...the temperature gets back to a value inside the range an SMS text message is sent to the phone numbers programmed in by the user containing the text Temperature OK When the temperature sensor is remov...

Page 8: ...sing the Mobeye SIM Portal a Sign up in the Mobeye Internet Portal b Activate the SIM card and the device c Program the settings and synchronise d Use of the portal and app 7 Programming when using yo...

Page 9: ...IES Insert the two batteries CR123 in the module Use the indication for the correct placement If you replace the batteries the settings will not be deleted since they are stored in the device memory 3...

Page 10: ...6 NETWORK CONNECTION AND PROGRAM MODE After placing the batteries and external power the Mobeye ThermoGuard will search for the network The outside LED flashes green and red This process normally take...

Page 11: ...tten on the plastic SIM card below the barcode You can take the entire number or only the last 8 digits If the SIM card and batteries are already installed a pop up will appear where you assign a name...

Page 12: ...irst blink red green while connecting to the network 4 4 BASICS OF THE MOBEYE INTERNET PORTAL Dashboard With multiple devices the dashboard shows all devices with the alarm messages in the last 24 hou...

Page 13: ...essages you link the contact persons who receive alarm and service messages via push notification call text message and or e mail Service messages can be warnings about missed test messages and low ba...

Page 14: ...to switch on arm the Mobeye ThermoGuard Press the button at the backside for 1 second The green LED blinks once every 3 seconds battery powered or stays on continuously in case of an external power su...

Page 15: ...upply 2 Press the outside button while reinserting the batteries Keep it pressed for about another 5 seconds 3 Release the button immediately after the LED starts to flash 4 If relevant connect the ex...

Page 16: ...t is disarmed The Mobeye Internet Portal expects the test message and checks the timely receipt The monitoring of the test messages follows the management by exception rule only if the message was not...

Page 17: ...gh quality digital temperature sensor is calibrated in the factory For special applications it is possible to calibrate the sensor and program a correction The adjusted temperature will be used in the...

Page 18: ...ize the urgency of the alarm messages all alarms can be repeated As long as the temperature value or an input has not returned to the inactive status the alarm messages will be repeated after the alar...

Page 19: ...Example to arm the system only during weekdays from 6AM to 7PM set the TIMEARM1 to 06 00 TIMEDISARM1 to 19 00 and DAYS1 to 12345 Only when using your own SIM card the DATE and TIME must also be set m...

Page 20: ...SIM card by default the ThermoGuard will call and send SMS text messages It is possible to suppress one of these By turning off the CALL the unit will only send SMS text messages By turning off the SM...

Page 21: ...yet In this program mode the device is ready to receive commands and settings In a battery operated unit a time out occurs if no correct command is received for 3 minutes after which the communication...

Page 22: ...system messages such as battery low and keep alive message The telephone number TEL1 is programmed via an SMS command This can be done from any telephone making it possible to program someone else s...

Page 23: ...he Mobeye ThermoGuard is in program mode Send an SMS text message to the unit with following content SMS command lower limit 1111 LTL example 1111 LTL 5 SMS command upper limit 1111 HTL example 1111 H...

Page 24: ...35 0 70 0 C OFF Higher limit temperature HTL 35 0 70 0 C OFF Temperature delay DELAYTEMP 000 999 min 0 Temperature calibration TOFFSET 5 0 5 0 C 0 Temperature unit TEMPUNIT C F C Input type input 1 T...

Page 25: ...emperature too low Alarm text high temperature TEXT2 20 characters Temperature too high Text alarm restore TEXT3 20 characters Temperature OK Alarm text input 1 TEXT4 20 characters Alarm 1 Alarm text...

Page 26: ...ks once every 3 seconds battery powered or stays on continuously in case of an external power supply If powered externally with network connection switching can be done via SMS commands SMS command to...

Page 27: ...s power and batteries The status can be requested by following SMS text message SMS command status request STATUS example 1111 STATUS LIST OF SETTINGS The settings can be requested by sending followin...

Page 28: ...replaced External power supply OK batteries OK The external power is restored or the adapter is plugged in a socket batteries do not need to be replaced delayed message If delayed message is added to...

Page 29: ...he network connection is established 2 flashes red every 3 seconds No GSM connection Try the SIM card in any mobile telephone replace SIM card using other telecom provider try the module at another lo...

Page 30: ...nd by max ca 500 mA Dimensions 94 x 94 x 28 mm Ambient temperature 10 C until 50 C Temperature sensor head 35 C tot 70 C This product is designed and manufactured in the Netherlands For more informati...

Page 31: ...30...

Page 32: ......