Mobeye Call-Key Installation Manual Download Page 13

11 

Users 

Users are contacts which are assigned to user groups. In this way the telephone numbers in 
the contacts are authorised for opening a lock by calling it. 
 
After the creation of user groups, the user can be 
assigned. Select ‘add user’.  
 
 
 
 
 
Choose a contact and assign it to one of the user 
groups. Select ‘Save’.  
 

Note: 

After  entering  the  settings  on  the  screen,  these 

are  not  automatically  programmed  in  the  Mobeye  Call 
Key.  This  only  happens  when  you  synchronize  the  data 
between the portal and the device. See section 2.8. 

2.8 SYNCHRONISATION OF DATA FROM AND TO THE DEVICE 

Each hour the Mobeye Call-Key will pick-up new settings from and send log data to the 
portal. Only after the data exchange new authorised numbers will be able to open the door.  
 
If synchronisation needs to be done immediately, the data exchange can be forced by: 
-  activation of an input (which will generate an alarm message to the contacts as well) 
-  removing the power supply (incl. batteries) and reconnecting this power(which will 

generate a power failure message to the contacts as well). 

2.9 HOW TO OPEN THE DOOR LOCK 

After the preceding steps the lock can be opened by authorised telephone numbers. 
 
If an authorised telephone number calls the number of the SIM card in the Mobeye Call-Key, 
the output relay(to which a lock is connected) will switch for a pulse time of 10 seconds 
(which can be changed). The unit will recognize the number and not take the phone; 
therefore, no costs will be involved.  
 
Comments: 

The portal shows the number which needs to be called to open the lock. 

T

he number recognition of the authorised number (‘caller’) must be switched on. 

The Mobeye SIM card is a European number (Spanish). The caller

’s telephone needs to 

allow ‘roaming’ (although no costs will be made). 

Each hour, during a few seconds, the data is exchanged. At this moment the lock cannot 
be opened. Please try again a few seconds later. 

If two people call the lock at the same time, it may happen that the lock cannot be 
opened. Please try again. 

2.10  HISTORICAL DATA  

 
Select ‘show all’ in the history to see historical data and 
who opened the lock at what moment. 
 

Summary of Contents for Call-Key

Page 1: ...Installation manual Mobeye Call Key GSM Door Opener In combination with Mobeye Internet Portal SW version 7 n...

Page 2: ...er than 55 C The device is intended for use in dry and clean places Protect the device from moisture heat and water splashing Not intended for external use The guidelines for the battery usage must be...

Page 3: ...ional settings 12 3 1 Standard behaviour 12 3 2 Installation code 13 3 3 Output behaviour Switch or pulse times 13 3 4 Input type 13 3 5 Input delay time 13 3 6 Inactive time 13 3 7 Alarm repeat time...

Page 4: ...SMS in the stand alone module Phone numbers are authorized for 24 7 always Registered in the Mobeye Internet Portal This password protected and secured internet area offers additional functionality Fo...

Page 5: ...he Mobeye M2M SIM card which was included in the delivery If no SIM card was included please ask Mobeye info mobeye eu The SIM card needs to be inserted before the batteries Open the back cover and in...

Page 6: ...ted the Mobeye Call Key will send an alarm message in the event of a power failure After sending the outage report the unit itself will go to the Low Power mode which means that the GSM module will sh...

Page 7: ...d Enter the SIM card number This is the number written on the plastic SIM card Only take the last 8 digits of the last two lines incl number after space do not insert the space Click next Select the d...

Page 8: ...tion code is also included in the confirmation SMS which the administrator received after programming the administrator number For more security the code needs to be changed to a personal installation...

Page 9: ...up was not done correctly click previous and try again If it still does not work please contact Mobeye info mobeye eu As soon as communication is set up next screen appears 1 Enter a name for the dev...

Page 10: ...Portal lists the active devices Select a device and click it Note After entering the settings on the screen these are not automatically programmed in the Mobeye Call Key This only happens when you sy...

Page 11: ...option not obligatory to set contact persons It is possible to connect several people to the messages It is possible to send alarm messages to a set of persons and the status messages to others Contac...

Page 12: ...of access scan be granted 1 Unlimited access 2 Limited access with periods and time windows 3 Limited access for an unlimited period but limited time windows within the days Create a group name For un...

Page 13: ...eries and reconnecting this power which will generate a power failure message to the contacts as well 2 9 HOW TO OPEN THE DOOR LOCK After the preceding steps the lock can be opened by authorised telep...

Page 14: ...n the Mobeye Internet Portal in the part Options The settings will be picked up by the unit at a synchronisation run see 2 8 To prepare the settings the security code is needed The factory default for...

Page 15: ...the time is set to 0 minutes the input is active again immediately after returning to the non alarm status If the time is set to e g 30 minutes the input remains inactive for the first 30 minutes If...

Page 16: ...ed to only switch the output by an incoming call or SMS from an authorized phone there is also an option to let them be switched by any incoming call SMS without being authorised To disable the need f...

Page 17: ...a beep is heard Setting SMS command Options Factory default Installation code INSTCODE 0000 9999 1111 Pulse time output 1 TO1 1 999 sec 10 Pulse time output 2 TO2 1 999 sec 10 Input type input 1 TYPE...

Page 18: ...Switch output 1 3 Input 1 triggered Send SMS call Message to portal call 4 Input 2 triggered Send SMS call Message to portal call 5 Power failure Send SMS call Message to portal call 6 Power restored...

Page 19: ...iver will hear a 2 tone signal and can confirm by pressing 1 4 3 PROGRAMMING ACTION RULES Send following SMS commands in following format CODE TRIGGER REACTION1 REACTION2 REACTION3 Do not forget the s...

Page 20: ...be deleted by an SMS by the command below incl index number The index number is the sequence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its...

Page 21: ...3 short beeps Release the button Connect the power and insert the batteries if available After a successful reset the status LED will flash red to indicate that the module is not configured The secur...

Page 22: ...e another network provider For other questions please refer to the site www mobeye eu Technical data GSM Quad Band EGSM 850 900 1800 1900 MHz compatible to the ETSI GSM Phase 2 standard Temperature ra...

Page 23: ...XM2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low vol...

Page 24: ......

Reviews: