© MOBATIME
29 / 104
800870.05
6.5.5
IRIG / AFNOR / DCF-FSK Output
1. Select mode: see picture below
2. Select time zone
see chapter 6.5.25 Time zone selection.
3. Configuration of the output voltage level (100 – 5500 mV):
The defined voltage corresponds to the expected output amplitude when power
matching (impedance matching) with a load of 50 Ohms is fulfilled. The output
voltage is not controlled, resp. it is not adjusted in case of a load change.
4. Configuration of the output voltage level supervision (0 – 2000 mV):
When the output voltage falls below the defined voltage level, an alarm is released.