© MOBATIME
26 / 104
800870.05
6.5.3
DCF / Pulse / Frequency output
1. Select line function: Line switched off, line DCF output, line pulse output, line
frequency output
2. Select time zone
see chapter 6.5.25 Time zone selection.
3. Select pulse mode: every second, minute, hour or user-defined.
(Only active with the pulse output function)
4. Select pulse length in ms (1-500ms)
(Only active with the pulse output function)
5. User-defined pulse interval (1-3600 sec) only active with pulse type 3 (=user) (the
value is also only then displayed). The pulse always occurs after a multiple of the
pulse interval from the 0 second in the 0 minute, e.g.:
– Pulse interval 960 sec. (16 min.)
Pulse occurs: 00:00:00, 00:16:00, 00:32:00, 00:48:00, 01:00:00, 01:16:00 ...
– Pulse interval 25sec
Pulse occurs: 00:00:00, 00:00:25, 00:00:50, 00:01:15, 00:01:40, 00:02:05 ...
... 00:59:35, 01:00:00, 01:00:25 ...
6. Output correction (-500ms...+500ms)
7. Frequency (1…5000 Hz)
Important:
Only frequencies which fulfill the following requirements are to be used,
otherwise, phase shifts occur:
20'000'000 / frequency = whole number value
Important:
Frequencies above 2 MHz are not sent out as a square-wave signal
anymore.