© MOBATIME
33 / 108
801104.05
6.5.8
DCF active code line
DCF active code line. Display of line 1 or 2.
DTS 4132.timeserver Moser-Baer AG
====================================
DCF ACTIVE CLOCK LINE 1
1 Line type DCF
2 Line on
3 Line mode 2
4 Time zone [+1] Brussel
5 Max. current 500mA
98 Return and save
99 Return and discard changes
Enter desired menu number>
Path: 2 Configuration
1 Outputs
6/7 MOBALine / impulse line 1/2
1. Select line type: 0 = MOBALine, 1 = Impulse line, 2 = DCF active code line
2. Select line function: Line switched off, line switched on
3. Select line mode: See the diagrams on the next page.
4. Select time zone (see chapter “6.5.28 Time zone selection“)
5. Select maximum current (0-1000mA) on the line. The line will be switched off as
long as the overcurrent is connected and restarted only on the next minute.
The maximum current is divided between both lines, i.e. it can always only be the
remainder at the most, that can be set as maximum current.
Important:
Changes can only be undertaken when the clock line is switched off!