© MOBATIME
16 / 40
800845.01
4
Setting the way of displayed time and date calculation
4.1
Basic setting – control according to source of synchronization
P3
A
Time zone is taken over according to the source
of synchronization
P4
2 – 12,
A
Synchronization signal type
P5
0
Neither MOBALine time zone nor Timezone-
server are used
P6
A
Display time and date according to source of
synchronization incl. daylight saving time
This setting is suitable for digital clocks synchronized by a DCF receiver or
controlled by a master clock as slave clock in a time distribution system. The
internal time zone table isn’t used.
4.2
Calculation using MOBALine time zones
This setting is suitable for digital clocks controlled by a master clock as a
MOBALine slave clock in a time distribution system with possibility to display
different MOBALine time zones
4.3
Calculation using Timezone-server MOBATIME
This setting is suitable for NTP digital clocks controlled by MOBATIME NTP
servers which support the Timezone-server functionality.
P3
A
Time zone is taken over according to the source of
synchronization. The UTC time calculation is based
on the MOBALine information.
P4
4
MOBALine
P5
1 - 20
Selection of the MOBALine time zone
P6
A
Display time and date according to chosen
MOBALine time zone, incl. daylight saving time
P3
A
NTP protocol uses UTC time zone
P4
11, 12
NTP multicast or unicast
P5
1 - 15
Selection of the Timezone-server time zone
P6
A
Display time and date according to chosen
Timezone-server time zone, incl. daylight saving
time