background image

© MOBATIME

8 / 12

800603.01

5. Serial Telegrams

5.1

Standard Time Telegram (IF 482) with Local Time

Definition:

Time telegram (ASCII), terminating at the designed second in the telegram:
9600 bit/s, 7 data bits, even parity, 1 stop bit. Jitter < 50 ms.

Format:
Byte Nr.

Designation

Sign

HEX Code

1

Stat sign

O

4F

2

Supervision

1)

A or M

41 or 4D

3

Time-Season 3)

W, S or L

57, 53 or 4C

4

Year tens

0 .. 9

30 .. 39

5

Year units

0 .. 9

30 .. 39

6

Month tens

0 or 1

31 or 31

7

Month units

0 .. 9

30 .. 39

8

Day tens

0 .. 3

30 .. 33

9

Day units

0 .. 9

30 .. 39

10

Monday .. Sunday 2)

1 .. 7

31 .. 37

11

Hours tens

0 .. 2

30 .. 32

12

Hours units

0 .. 9

30 .. 39

13

Minutes tens

0 .. 5

30 .. 35

14

Minutes units

0 .. 9

30 .. 39

15

Seconds tens

0 .. 5

30 .. 35

16

Seconds units

0 .. 9

30 .. 39

17

Telegram end

CR

0D

1) 'A': Correct time code reception from the transmitter. 'M': No time signal has been received during

more than 12 hours (Time will be taken over at 'A' and 'M').

2) Weekday not evaluated by BU 190(t).

3)

W

inter,

S

ummer or

L

ocal time: Will be checked but not evaluated.

Summary of Contents for BU 190 230

Page 1: ...MOBATIME BE 800603 01 Installation and Operating BU 190 t 230 Movement for DCF MSF time code Please read this instructions carefully before installation...

Page 2: ...y and start the setting up of the product only once you have correct ly understood all information for the installation and of the operation 5 The installation must only be carried out by skilled staf...

Page 3: ...of hands and Starting up 5 3 2 1 Mounting of hands 5 3 2 2 Starting up and check of the hand position 6 4 Setting up Connections 6 4 1 Synchronization with DCF or MSF time code 6 4 2 Synchronization w...

Page 4: ...0t 230 201405 Minute hand Hour hand 12 3 BU 190t 230 Cover glas 35 5 10 136 5 67 5 Disc nuts Clock dial Fig 1 Fig 2 Cable length 550mm Power AC 230V BU 190 230 BU 190t 230 10 136 5 67 5 94 35 9 4 13 7...

Page 5: ...nnection of an MSF 60 radio receiver Rugby as well Serial input RS 232 422 for time setting and synchronization with standard ASCII time tele gram definition IF482 3 Mounting guidelines 3 1 Mounting o...

Page 6: ...tion of the clock is OK reset DIP Switch 1 to OFF position Fig 5 The movement can be synchronized with following time codes DCF MSF see chapter 4 1 Serial time telegram standard IF 482 telegram by RS...

Page 7: ...10 Fig 11 Fig 9 IF 487 LED OFF ON DCF BU 190 t 230 1 2 3 4 5 6 7 8 ON Option 2 Option 1 MEZ Time zone Zeitzone MEZ Time zone Zeitzone DCF Antenna Antenne Stop Mode Second hand Wobbling Schritt Sekunde...

Page 8: ...0 39 5 Year units 0 9 30 39 6 Month tens 0 or 1 31 or 31 7 Month units 0 9 30 39 8 Day tens 0 3 30 33 9 Day units 0 9 30 39 10 Monday Sunday 2 1 7 31 37 11 Hours tens 0 2 30 32 12 Hours units 0 9 30 3...

Page 9: ...utes maximum serial 3 5 seconds radio signal 3 5 minutes 10 seconds 6 minutes 5 5 minutes maximum Operation mode minute shaft 1 step every 60 s Operation mode hour shaft continuous Operation voltage 2...

Page 10: ...MOBATIME 10 12 800603 01...

Page 11: ...MOBATIME 11 12 800603 01...

Page 12: ...www mobatime com SALES SWITZERLAND MOBATIME AG Stettbachstrasse 5 CH 8600 D bendorf Tel 41 44 802 75 75 Fax 41 44 802 75 65 info d mobatime ch www mobatime ch MOBATIME SA En Budron H 20 CH 1052 Le Mon...

Reviews: