![Mobatime BU 190 230 Installation And Operating Download Page 7](http://html1.mh-extra.com/html/mobatime/bu-190-230/bu-190-230_installation-and-operating_1814675007.webp)
© MOBATIME
7 / 12
800603.01
Connection to
the mains
supply should
be realized
according to
the class II
protection.
Control of the reception quality:
The orientation of the radio time signal receiver should be chosen in a way, the LED of the receiver
flashes regularly (at good reception quality the LED in the receiver flashes regularly in second
rhythm), see also the instruction manual of the receiver.
The movement starts after about 5 minutes and set itself automatically on the exact time.
4.2
Synchronization with serial time telegram (IF 482)
The movement can be synchronized with RS 432 or RS 485 over standard-RS 485 telegram. Time
will be interpreted and shown as local time. See chapter 5.1 for telegram definition.
1
TTL IN (RxD)
2
GND
3
RS-232 IN (RxD)
4
nc
5
RS-422 IN (RD +)
6
RS-422 IN (RD -)
View from contact side
4.3
Connection / cascading
To connect the radio signal to a double sided clock (two movements), there are two possibilities:
Possibility 1: The radio signal can be distributed on both movements with a DCF multipler
(Art.No. 35 821) (Fig. 11).
Possibility 2: The time signal is sent to the second movement over a "COM 192" cable (Art. No.
200045). Therefore the signal is connected from the OUT-plug of the master-movement
to the IN-plug of the slave movement (Fig.10). Disadvantage: If master-movement fails,
slave-movement will also stop.
IRIG-B / AFNOR
DCF - FSK
DCF Radio
Receiver
1
2
3
4
5
6
Fig. 10
Fig. 11
Fig. 9
IF 487
LED
O F
F
O N
DCF
BU 190(t) 230
1
2
3
4
5
6
7
8
O
N
Opt ion 2
Opt ion 1
MEZ
Time z one / Zeitzone
MEZ
Time z one / Zeit zone
DCF
Ant enna / Antenne
St op Mode
Second hand /
Wobbling / S chrit t
Sekundenzeiger
normal
Clock hands / Zei ger
ME Z -1
ME Z +1
MS F
None s t op / ohne S top
Cont. / K onti nuierl ich
12.00 P os it ion
23 0 V ±1 0% ; 5 0-6 0 Hz; 10 mA
BU 19 0t 230
A/N: 200 840 .02
P/N: 039 59 66 5 001
OUT
IN
DC F
+ / -
AC
23 0 V
COM 192
AC
230V
AC
230V
BU 190(t) 230
1
2
3
4
5
6
7
8
O
N
Opt ion 2
Opt ion 1
MEZ
Time z one / Zeitzone
MEZ
Time z one / Zeit zone
DCF
Ant enna / Antenne
St op Mode
Second hand /
Wobbling / S chrit t
Sekundenzeiger
normal
Cloc khands / Zei ger
ME Z -1
ME Z +1
MS F
None s t op / ohne S top
Cont. / K onti nuierl ic h
12.00 P os it ion
23 0 V ±1 0% ; 5 0-6 0 Hz; 10 mA
BU 19 0t 230
A/N: 200 840 .02
P/N: 039 59 66 5 001
OUT
IN
DCF
+ / -
AC
23 0 V
+
-
+
-
+
-
ant.
out 1
out 2
35
82
1
DCF
Multipler
+
-
master
AC
230V
BU 190(t) 230
1
2
3
4
5
6
7
8
O
N
Option 2
Option 1
MEZ
Time zone / Zeitzone
MEZ
Time zone / Zeitzone
DCF
Antenna / Antenne
Stop Mode
Second hand /
Wobbling / Schritt
Sekundenzeiger
normal
Clock hands / Zeiger
MEZ - 1
MEZ +1
MSF
None stop / ohne Stop
Cont. / Kont inuierlich
12.00 Position
230 V ±10%; 50-60 Hz; 10 m A
BU 190t 230
A/N: 2 00 840.02
P/N: 03959665 001
OUT
I N
DCF
+ / -
AC
230 V
BU 190(t) 230
1
2
3
4
5
6
7
8
O
N
Option 2
Option 1
MEZ
Time zone / Zeitzone
MEZ
Time zone / Zeitzone
DCF
Antenna / Antenne
Stop Mode
Second hand /
Wobbling / Schritt
Sekundenzeiger
normal
Clock hands / Zeiger
MEZ -1
MEZ +1
MSF
None stop / o hne Stop
Cont. / Kontinuierlich
12.00 P osition
230 V ±10%; 50-6 0 Hz; 10 mA
BU 190t 230
A/N: 200 8 40.02
P/N: 0 3959665 001
OUT
IN
DCF
+ / -
AC
230 V
Movement 1
Movement 2
DCF 4500
Summary of Contents for BU 190 230
Page 10: ...MOBATIME 10 12 800603 01...
Page 11: ...MOBATIME 11 12 800603 01...