6
INSTALLATION
The hand dryer has been specifically designed for vertical attachment on the wall
with the air outlet toward the bottom.
The appliance can also be installed by connecting it permanently to the power
supply, using the hole “D” in Fig. 3. In this case an overvoltage category III bipo-
lar circuit breaker, with contact opening distance of at least 3 mm must be fitted
upstream from the supply line.
Make sure that the wall where you plan to mount the appliance is solid and free
of electrical cables or water pipes inside.
For safety reasons, never attach the device near bath tubs, wash basins, show-
ers, or other fittings where there may be water.
This hand dryer must be installed out of the range of a person using the bath or
the shower.
This machine can be installed and used in bathroom, washroom, kitchen, etc. The distance
shall be around 110 cm from the ground. Keep certain distance between the dryer and the
door to avoid hit when opening and closing the door.
1. Drill 4 holes (diameter 6 mm, depth 35 mm) in the wall according to Fig. 3 and bury the
expansion tubes into the holes.
2. Screw out the 2 screws on the right and the left (Fig. 1) and discharge the shell (Fig. 2).
3. Fix the holder to the wall by means of the 4 fixing screw enclosed with the appliance;
then fasten the shell to the holder; make sure that the air outlet on the shell and on the
holder be fixed each other very well.
4. The power cord can be fixed to the base of the appliance and can pass through the base
itself. The connection diagram is shown in Fig. 4: Pos. A: Earth wire bicolor; Pos. B: live
wire (L); Pos. C: neutral wire (N).
5. Connect the power cord to the electrical supply.
OPERATING
The hand dryer works automatically. After washing your hands, put them near to the wind
hole, located at the bottom. The warm air flows immediately. As your hands leave the air out-
let, the appliance automatically stops, in order to avoid infection of germs. A safety device
causes automatic shutdown after 60 seconds of continuous use. To short the work time,
please shake the water away from your hands before the use.
TECHNICAL DATA
Power supply
AC 230 V ~ 50 Hz
Rated power
1800 W
Air speed
60 m/s
Detection range
50
÷
200 mm
Protection level
IPX1
Dimensions (cm)
29.5 x 17 x 32.5 (H)
Summary of Contents for 726