8
I
:
J
:
VII Setup signal enhancer
HY2611D is used for enlarge system coverage. Add one signal enhancer; the coverage will
enlarge to twice of the former distance.
1)
Remember the feature code of Requester
The enhancer can remember 80 feature codes of Requester, when it receives information
from Requesters, it will judge whether the information is in its control sphere, if so, it
enhance the signal, if not, it won’t work.
The set-up process is as following
:
After connect to power, press the button of TX for 4 seconds, then TX light will shiny. This
means it enters to remember state, then press the calling button of Requester which is need to
be remembered, if the TX light flash, it mans remember successfully.
If press the button of TX once, then the TX light will put out, which means withdrew from
remember state.
2)
Delete the feature code of Requester
When you don’t need the enhancer to control some requesters, you can delete corresponding
remember from enhancer
The deleting process is as following
:
After connect to power, press the button of RX for 4 seconds, then RX light will shiny. This
means it enters to delete state, then press the calling button of Requester, which is needed to
be deleted, if the RX light flash, it mans delete successfully.
If press the button of RX once, then the RX light will put out, which means withdrew from
delete state.