Error Code
Cause and Action
Firmware or hardware problem. The tape drive determined that a firmware or tape drive
hardware failure occurred.
Tape drive hardware problem. The drive determined that a tape path or read/write error occurred.
To prevent damage to the drive or tape, you cannot insert a cartridge if the current cartridge was
successfully ejected. The error code might clear when you cycle power to mRack DIT.
Tape drive or media error. The tape drive determined that an error occurred, but it cannot isolate
the error to faulty hardware or to the tape cartridge. Ensure that the tape cartridge is the correct
media type:
Ultrium 1, 2, 3, and 4 cartridges are not supported in mRack DIT LTO-7 models.
Ultrium 1,2 and 3 cartridges are not supported in mRack DIT LTO-6 models.
Drive does not accept an expired Cleaning Cartridge.
Media error. The tape drive determined an error occurred because of a faulty tape cartridge or
an invalid tape cartridge. Ensure that the tape cartridge is the correct media type:
Ultrium 1, 2, 3, and 4 cartridges are not supported in mRack DIT LTO-7 models.
Ultrium 1,2 and 3 cartridges are not supported in mRack DIT LTO-6 models.
Drive does not accept an expired Cleaning Cartridge.
Interface problem. The tape drive determined that a failure occurred in the tape drive 's
hardware or in the host bus.
Tape drive or RS-422 error. The tape drive determined that a failure occurred in the tape drive 's
hardware or in the RS-422 connection.