5  OPERATING NOTE 

5.1  Power on the Modem 

After plugin the power adapter, the modem is usually fully operational within 4 seconds, after

 

powering it up. Depending on the signal strength of the network in the area, logging into a 
network may take longer and is outside the control of the modem. 

5.2  Reset to default 

Press reset button, it will be reset to default. All of temporary data buffer will be clear. 

5.3  External input x2 

External signal input source, positive signal are DI1 and DI2, negative signal are COM_1 are COM_2. 
Power input range is +12V~+48V, it will be determined as positive. It can be used for alert. 

5.4  External Relay x1 

Non positive and negative signal relay output, maximum power input voltage range is +48V. It can be 
used for beeper. 

5.5  DB9 Connector 

The RS-232/422/485 connector is DB9 male type, please refer to table 4. 

5.6  Install SIM card 

Please  turn to  back  view,  screw  open the  cover,  then  user  will  see  SIM  card  holder.  Please  use  SIM 
card faces to PCB board and put it into holder, please screw the cover back. 

Summary of Contents for MLB-G4201

Page 1: ...td herein known as the company is believed to be accurate and reliable However the company assumes no responsibility for its use nor any infringement of patents or other rights of third parties which...

Page 2: ...s scanning and or information storage and retrieval systems for any purpose without the expressed written consent of the company WARNING The MLiS GSM wireless terminal is a RF product intended for int...

Page 3: ...2 MECHANICAL DESCRIPTION 12 2 1 Overview 12 2 2 Dimensions 12 3 ELECTRICAL INTERFACE DESCRIPTIONS 13 3 1 Right side view DB9 connector 13 3 2 Left side view DC Jack Industry connector 14 3 3 Frond vi...

Page 4: ...5 2 AT command 32 4 5 3 Password 33 4 6 Update FW 34 4 7 Reset to Default 34 4 8 Status 35 4 8 1 IO Relay Status 35 4 8 2 IPSec Log OpenVPN Log Syslog 35 4 9 Save 36 5 OPERATING NOTE 37 5 1 Power on t...

Page 5: ...85 for MLB G4201 13 Figure 4 DC and Industry connector for MLB G4201 14 Figure 5 Antenna Connector for MLB G4201 15 Figure 6 SIM Card Holder for MLB G4201 17 List of Tables Table 1 Chassis Dimensions...

Page 6: ...vide power input LEDs are used to indicate the status of the wireless terminal The MLB G4201 wireless terminal can be used to provide a wireless communication link to many applications including meter...

Page 7: ...W x H 119 5 x 89 x 26 9mm excluding connectors Weight 425g Casing Material Metal SMS MT MO Cell Broadcast Text and PDU mode Serial Parameter Data Bits 5 6 7 8 Stop Bits 1 1 5 2 Parity None Even Odd S...

Page 8: ...MLB G4201 Wireless Terminal User Manual 8 Rev 1 1 Data Delimiter Yes Data Length Packing Yes MCCP MCCU Yes API MLiS Cellular Control Protocol MCCP Utility MLiS Cellular Control Utility MCCU...

Page 9: ...consists of a fully certified CE NCC approved GSM GPRS engine SIM card holder and power regulator The wireless terminal is supplied with power via the DC jack The remaining DB9 connector is used for d...

Page 10: ...1 30dBm 2dB for GSM1800 Class 1 30dBm 2dB for GSM1900 Class E2 27dBm 3dB for GSM 850 8 PSK Class E2 27dBm 3dB for GSM 900 8 PSK Class E2 26dBm 3 4dB for GSM 1800 8 PSK Class E2 26dBm 3 4dB for GSM 19...

Page 11: ...de TCP UDP 11 Serial Interface DB9 connector 8 wire Modem Interface with status and control lines unbalanced asynchronous Fixed bit rate 1 200bps to 230 400bps Flow Control Hardware RTS0 CTS0 and Soft...

Page 12: ...ical design of the wireless terminal along with the positions of the different connectors 2 2 Dimensions Figure 2 Chassis Dimension for MLB G4201 S N Parameter Value 1 Height H 48mm 2 Length L 121mm 3...

Page 13: ...v 1 1 3 ELECTRICAL INTERFACE DESCRIPTIONS 3 1 Right side view DB9 connector Figure 3 RS232 RS422 RS485 for MLB G4201 The table below defines the RS 232 422 485 pin configuration on the wireless termin...

Page 14: ...wer of TB is same as input power Do Not use DC PWR to be the input power at the same time it may cause damage to the equipment Relay External Relay max 40V DI1 I1 COM_1 Pin 5 is Pin 6 is I1 external s...

Page 15: ...n PWR1 DC Green On Power is being supplied from power input 1 PWR2 Terminal Block Green On Power is being supplied from power input 2 READY Green On System startup is complete and the system is operat...

Page 16: ...not inserted or PIN code is incorrect SIM2 Amber On Off SIM 2 is active or inactive Blink SIM 2 is not inserted or PIN code is incorrect 3G Amber On Registered to a base station with cellular connecti...

Page 17: ...type which can be locked It can be accessed through removing the battery cover as shown below Figure 6 SIM Card Holder for MLB G4201 Be sure to power off the modem when user replaces the SIM card Oth...

Page 18: ...Started HW installation Step 1 Please insert SIM card into SIM card holder as follows Be sure to power off the modem when user replaces the SIM card Otherwise it may cause damage to the equipment Ste...

Page 19: ...usually fully operational within 30 seconds after powering it up Depending on the signal strength of the network in the area logging into a network may take longer and is outside the control of the wi...

Page 20: ...cable to configure MLB G4201 4 1 Web Console Set PC MLB G4201 into same subnetwork The Default IP of MLB G4201 is 10 0 10 1 Please set up your PC with the same network segment such as 10 0 10 2 So yo...

Page 21: ...formation of MLB G4201 4 2 1System Info Item Description Model name Display the model name Device name Display the device name Serial No Display the serial number System up time Display system run tim...

Page 22: ...tion Device MAC address Display physical address IP address Display the IP address Subnet Mask Display the subnet mask 4 2 3 Cellular Info Item Description Cellular RSSI Signal Cellular WAN IP address...

Page 23: ...ttings Item Description IP Address Enter the unique IP address for the MLB G4201 Subnet mask Enter the subnet mask to specify the type of network Primary DNS server Enter the IP address of the primary...

Page 24: ...ttings Item Description APN Access Point Name PIN Personal Identification Number Authentication Protocol Username Password Item Description APN Access point name PIN Personal identification number Aut...

Page 25: ...Primary DNS server Set IP address of the primary DNS server Second DNS server Set IP address of the secondary DNS server Start IP address Enter the starting IP address in the IP address pool Maximum...

Page 26: ...address 2 Enable the mapping setting 3 Click Apply to save settings Apply Click to save all settings 4 3 4Port Forwarding Item Description Static DHCP mapping 1 Select Protocol and input Public Port I...

Page 27: ...able to increase the functionality of your MLB G4201 and wireless network system 4 4 1 Com Port Setting Item Description COM Port setting 1 Select Working Mode Transport Mode Baud Rate Parity Data Bit...

Page 28: ...eless Terminal User Manual 28 Rev 1 1 4 4 2 IPsec base VPN Setting Item Description IPSec Enable Select Enable to enable the IPsec function Edit Click Edit to create IPsec settings Apply Click to save...

Page 29: ...server subnet IP of the local network Local netmask Enter the remote VPN server subnet netmask of the local network Local ID Enter an ID to identify and authenticate the local VPN gateway Remote VPN...

Page 30: ...authentication mode you select Encryption algorithm Select the DES 3DES or AES128 algorithm for the VPN ISAKMP phase 1 encryption mode Hash algorithm Select the MD5 or SHA 1 VPN key exchange phase 1...

Page 31: ...e the Dead Peer Detection DPD feature the OnCell G3470A LTE performs one of the following actions when connection to a remote IPSec tunnel is down Hold Keep the VPN tunnel Clear Clear the VPN tunnel R...

Page 32: ...ired wireless networks 4 5 1 Ping Item Description Destination Inputting a node s IP address in the Destination field you can use the ping command to make sure it exists and whether or not the access...

Page 33: ...Rev 1 1 4 5 3 Password Item Description Current Password Input current password New password Input new password Confirm the new password Input new password again Apply Click Apply to change password...

Page 34: ...nhanced with more value added functions by installing firmware upgrades Please contact MLiS website to get latest firmware Item Description Firmware File Click to load fw file Upload Click to upgrade...

Page 35: ...anual 35 Rev 1 1 4 8 Status 4 8 1 IO Relay Status Item Description DI1 Click GET to gather the status of DI1 DI2 Click GET to gather the status of DI2 Relay Trigger the Relay to enable disable relay 4...

Page 36: ...Manual 36 Rev 1 1 Syslog Item Description IPSec Log Record the IPSec log OpenVPN Log Record the OpenVPN log Sysloog Record the syslog 4 9 Save Item Description Save Click Save to save all setting you...

Page 37: ...will be clear 5 3 External input x2 External signal input source positive signal are DI1 and DI2 negative signal are COM_1 are COM_2 Power input range is 12V 48V it will be determined as positive It c...

Page 38: ...4C 42 2D 43 4F 4E 46 49 47 53 54 41 47 45 31 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 9D MLB CONFIGSTAGE2 Waiting for IN STAGE2 HEX 4D 4C 42 2...

Page 39: ...MLB G4201 Wireless Terminal User Manual 39 Rev 1 1 MCCP Setting Process via Internet RS 232 MCCP Setting Process via SMS using admin phone number...

Page 40: ...End Tag Z Example MLB CONNECTIONPROFILE 6 2 192 168 100 99 27000 1 Z set 192 168 100 99 port 27000 to profile 2 for TCP Client Mode enabled Read Command Header MLB CONNECTIONPROFILE Connection Type 1...

Page 41: ...one 2 ODD 3 EVEN Stop Bit 1 1 bit 2 2 bit HW Flow Control 0 Disable 1 Enable DTR Level 0 High Level 1 Low Level RTS Level 1 High Level 2 Low Level End Tag Z Example MLB CONNECTIONPROFILE 6 2 192 168 1...

Page 42: ...Enable DTR Level 1 High Level 2 Low Level RTS Level 1 High Level 2 Low Level End Tag Z Response format Response UART Mode Baud rate Parity Bit Stop Bit HW Flow Control Disable Enable DTR H L RTS H L...

Page 43: ...et UDP Client Mode 6 Socket TCP Client Mode 7 Socket TCP Server Mode End Tag Z Example MLB INTERNETSETTING internet user123 pass456 2 Z set APN internet User Name user123 Password pass456 Internet con...

Page 44: ...Event 6 Admin End Tag Z Response format Response Phone Number Phone Event Example Send MLB PHONESETTING 2 Z Response 886935123456 1 886935123456 is the event of Off Line that has been enabled Reconnec...

Page 45: ...Time Interval Example Send MLB RECONNECTSETTING Z Response 9999 5 Connecting maximum retry time is no limit and retry interval is 5 minutes Packing Setting Write Command Header MLB PACKINGSETTING Dev...

Page 46: ...ponse Format Response Retry Time Retry Time Interval Example Send MLB REPORTDIOXSETTING Z Response SMS The DIO status will be reported via SMS Get DIO Write Command Header MLB GETDIOX DIO Number 1 DIO...

Page 47: ...6717 E info schmidthk com Shenzhen China Schmidt Co China Ltd Shenzhen Branch Schmidt Shenzhen Co Ltd 3 F Unit E International Culture Building Fu Tian Road Shenzhen 518033 T 86 755 8376 0232 F 86 75...

Page 48: ...DC jack 5 5 2 1 MLA PSP 101 US Adapter Plug MLA PSP 104 British Adapter Plug MLA PSP 103 European Adapter Plug MLA PSP 102 Australia Adapter Plug MLA CAB 001 DC Jack power line 5 5 2 1 Cable MLA CAB 1...

Page 49: ...t Taiwan 886 2 2502 5095 China 86 755 8376 0232 Singapore 65 6272 7233 Email sales mlis schmidtelectronics com Official Website MLiS Website www schmidtm2m com Support www schmidtm2m com support Downl...

Reviews: