Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the 

product. 

This product is non-dimmable. 

This product should be dismantled for disposal when it reaches the end of its life. Please see website for 

dismantling instructions. 

This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities 

for where facilities exist.  

The batteries in this luminaire are Nickel Cadmium and must be disposed of correctly. Please contact the local 

authorities for the disposal of this toxic waste. 

WARRANTY

 

This product has a warranty of 1 year

 

from date of purchase. Failure to install this product in accordance with 

the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will 

invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of 

purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation 

costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve 

the right to alter product specification without prior notice. 

TESTING FOR EMERGENCY LUMINAIRES 

 

Recommended routine test procedure in accordance with BS5266  

  Daily check – check LED charge indicator is illuminated 

  Monthly functional test - simulate a mains supply failure for approx. 30 seconds by operation of key switch 

or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge indicator is 

illuminated 

  Annual three hour duration test - simulate a mains supply failure for three hour continuous test by operation 

of key switch or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge 

indicator is illuminated 

  If the luminaire fails any of the above tests, please contact a qualified electrician. See below for test record 

sheet 

 

GENERAL

WARNING

This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 
testing. Irreparable damage will occur if this instruction is not followed.
The louvre is easily marked by handling, the protective glove provided should be used

This product contains a control gear which can be replaced by a professional.

 

INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following products: 

SURF236EMHF / SURF258EMHF / SURF270EMHF 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of 

the circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

This product is for indoor use only 

 

This product is Class I and must be earthed 

 

This product is IP20 rated 

INSTALLATION 

 

Provide power to the required point of installation  

 

Using the plastic glove provided carefully remove the louvre by pressing in the retaining clips 

 

Mark the location of the fixing holes and drill the holes ensuring not to infringe with any gas / water 

pipes or electrical cables 

 

Feed the mains cable through the cable entry point on the luminaire 

 

Secure the luminaire to the surface 

 

Connect to the mains supply ensuring the correct polarity is observed: L - Live, SL - Switched Live 

(brown), E - Earth (green & yellow), N - Neutral (blue) (see Fig. 1) 

 

 

Insert 2 x suitable T8 fluorescent lamps 

 

Connect the earth flylead to the louvre and click the louvre into place 

 

Switch on and check for correct operation, ensuring the green indicator LED is illuminated 

 

We recommend, on commissioning the installation, a minimum charge period of 24 hours before 

carrying out an emergency duration test 

 

If the batteries have been left in a discharged state for an extended period, we recommend that one or 

more charge and discharge cycles are completed which should help to restore the battery capacity 

 

WARNING 

This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 

testing. Irreparable damage will occur if this instruction is not followed. 

The louvre is easily marked by handling, the protective glove provided should be used 

GENERAL 

This product contains a control gear which can be replaced by a professional. 

 

Fig. 1

• Insert 2 x suitable T8 fluorescent lamps
• Connect the earth flylead to the louvre and click the louvre into place
• Switch on and check for correct operation, ensuring the green indicator LED is illuminated
• We recommend, on commissioning the installation, a minimum charge period of 24 hours before carrying 

out an emergency duration test

• If the batteries have been left in a discharged state for an extended period, we recommend that one or more 

charge and discharge cycles are completed which should help to restore the battery capacity