• The spike of the luminaire is required to be pushed fully into the ground
• The fittings must be wired
IN SERIES
to the secondary side of the constant current driver (see Fig. 2). The
minimum and maximum load of the driver must be observed
Fig. 2
•
For wall mounting, using the bracket as a template, mark the location for, and drill the fixing holes
ensuring not to infringe with any gas/water pipes or electrical cables (see Fig. 3)
Fig. 3
•
Connect the luminaire to the mains supply ensuring the correct polarity is observed: L
–
Live (brown),
E
–
Earth (green/yellow), N
–
Neutral (blue)
•
Switch on and check for correct operation
WARNING
This luminaire must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
This product is not suitable for installation in or near a coastal or marine environment.
GENERAL
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole
luminaire should be replaced.
Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not use
aggressive cleaning products or solvents which may damage the product.
Do not use any source of high-pressure washers to maintain or clean this product.
A light film of acid free oil is recommended after installation and maintained periodically (2-3 times a year) to aid
corrosion prevention.
This product is non-dimmable.
Fig. 1
Fig. 2
• Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP
rated junction boxes should be used where required
• Choose a position for the luminaire ensuring the ground is suitable to firmly hold the spike and luminaire
in position. Check the ground is not liable to flooding and the spike does not infringe with any underground
pipes or cables
• The body of the product should not rest directly on the ground
• The preinstalled cable supplied is for above-ground use only. Cables that are to be routed within walls or
below ground must be protected by means of suitable conduit or trunking (see Fig. 1)
Fig. 2
•
We recommend that a maximum cable run of 10m of 0.75mm
2
CSA cable be used in the series circuit
•
The junction box IP68JBS (not included) can be used for the connection of up to three fittings at a time
•
Connect the + (brown) and
–
(blue) ends of the series loop into the secondary terminals of the constant
current driver
•
Connect the constant current driver to the mains supply ensuring the correct polarity is observed:
Live (brown), Neutral (blue)
•
Switch on and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
Care must be taken if these fittings are to be installed in a special location as defined by BS7671. This is
because the maximum secondary voltage of the driver may exceed the maximum voltage requirements of the
location.
This product is not suitable for installation in or near a coastal or marine environment.
GENERAL
This product contains a light source of energy efficiency class F to Regulation (EU) No. 2019/2015 and (UK)
2021 No. 1095.
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole
luminaire should be replaced.
Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not
use aggressive cleaning products or solvents which may damage the product.
Do not use any source of high-pressure washers to maintain or clean this luminaire.
A light film of acid-free oil is recommended after installation and maintained periodically (2-3 times a year) to aid
corrosion prevention.
This product is non-dimmable.
This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities
for where facilities exist.
WARRANTY
This product has a warranty of 1
year
from date of purchase. Failure to install this product in accordance with
the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will
invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of
purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve
the right to alter product specification without prior notice.
350mA, IP65, Class III, Non-Dim, Ta -25~45