background image

• The spike of the luminaire is required to be pushed fully into the ground 
• The fittings must be wired 

IN SERIES

 to the secondary side of the constant current driver (see Fig. 2). The 

minimum and maximum load of the driver must be observed 

 

 

Fig. 2 

 

 

For wall mounting, using the bracket as a template, mark the location for, and drill the fixing holes 

ensuring not to infringe with any gas/water pipes or electrical cables (see Fig. 3) 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3 

 

 

Connect the luminaire to the mains supply ensuring the correct polarity is observed: L 

 Live (brown), 

 Earth (green/yellow), N 

 Neutral (blue) 

 

Switch on and check for correct operation 

 
WARNING 

This luminaire must be disconnected from the circuit if subjected to any high voltage or insulation resistance 

testing. Irreparable damage will occur if this instruction is not followed. 

This product is not suitable for installation in or near a coastal or marine environment. 

GENERAL 

The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole 

luminaire should be replaced. 

 

Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not use 

aggressive cleaning products or solvents which may damage the product.   

Do not use any source of high-pressure washers to maintain or clean this product. 

A light film of acid free oil is recommended after installation and maintained periodically (2-3 times a year) to aid 

corrosion prevention. 

This product is non-dimmable. 

Fig. 1

Fig. 2

• Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP 

rated junction boxes should be used where required 

• Choose a position for the luminaire ensuring the ground is suitable to firmly hold the spike and luminaire 

in position. Check the ground is not liable to flooding and the spike does not infringe with any underground 
pipes or cables 

• The body of the product should not rest directly on the ground  
• The preinstalled cable supplied is for above-ground use only. Cables that are to be routed within walls or 

below ground must be protected by means of suitable conduit or trunking (see Fig. 1)

 

 

Fig. 2 

 

We recommend that a maximum cable run of 10m of 0.75mm

2

 CSA cable be used in the series circuit 

 

The junction box IP68JBS (not included) can be used for the connection of up to three fittings at a time 

 

Connect the + (brown) and 

 (blue) ends of the series loop into the secondary terminals of the constant 

current driver 

 

Connect the constant current driver to the mains supply ensuring the correct polarity is observed: 

Live (brown), Neutral (blue) 

 

Switch on and check for correct operation 

WARNING 

This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 

testing. Irreparable damage will occur if this instruction is not followed. 

Care must be taken if these fittings are to be installed in a special location as defined by BS7671. This is 

because the maximum secondary voltage of the driver may exceed the maximum voltage requirements of the 

location. 

This product is not suitable for installation in or near a coastal or marine environment. 

GENERAL 

This product contains a light source of energy efficiency class F to Regulation (EU) No. 2019/2015 and (UK)

 

2021 No. 1095.

 

The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole 

luminaire should be replaced. 

 

Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not 

use aggressive cleaning products or solvents which may damage the product.   

Do not use any source of high-pressure washers to maintain or clean this luminaire. 

A light film of acid-free oil is recommended after installation and maintained periodically (2-3 times a year) to aid 

corrosion prevention. 

This product is non-dimmable. 

This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities 

for where facilities exist.  

WARRANTY

 

This product has a warranty of 1

 

year

 

from date of purchase. Failure to install this product in accordance with 

the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will 

invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of 

purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation 

costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve 

the right to alter product specification without prior notice. 

350mA, IP65, Class III, Non-Dim, Ta -25~45 

 

DCDEC21_V3 