These instructions should be read carefully and retained after installation by the end user for 
future reference and maintenance. 
These instructions should be used to aid installation of the following products: 
LWR2G / LWR2W / LWR4G / LWR4W / LWS2G / LWS2W / LWS4G / LWS4W 

GENERAL INSTRUCTIONS

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) 

and current Building Regulations. If in any doubt, consult a qualified electrician 

 Please isolate mains prior to installation or maintenance 

 Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the 

circuit cable, fuse or circuit breaker 

 Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 This product is Class II double insulated  

 This product is IP44 rated 

SAFETY

INSTALLATION

Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires. 

 Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP 

rated junction boxes should be used where required 

 Remove the mounting bracket from the luminaire with the aid of the Allen key supplied 

 Using the mounting bracket as a template, mark the location for, and drill the fixing holes ensuring not to 

infringe with any gas/water pipes or electrical cables 

 Remove the backplate from the luminaire to access the PCB and mains terminals 

Summary of Contents for LWR2G

Page 1: ...INSTALLATION MAINTENANCE MANUAL LWR2G LWR2W LWR4G LWR4W LWS2G LWS2W LWS4G LWS4W ...

Page 2: ... breaker Please note the IP Ingress Protection rating of this product when deciding the location for installation This product is Class II double insulated This product is IP44 rated SAFETY INSTALLATION Note If this product is being used in conjunction with an external PIR or sensor please confirm with the manufacturer of the sensors that they are compatible with LED luminaires Provide power to th...

Page 3: ... the rubber grommet to retain IP rating and secure the backplate to surface Connect the luminaire to the mains supply ensuring the correct polarity is observed see Fig 1 L Live brown N Neutral blue Fig 1 Replace the backplate ensuring the gasket is in place and not damaged Secure the luminaire to the mounting bracket Switch on and check for correct operation NING product must be disconnected from ...

Page 4: ...rgy efficiency class G to Regulation EU No 2019 2015 and UK 2021 No 1095 This product contains an LED light source and a control gear which can be replaced by a professional Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only do not use aggressive cleaning products or solvents which may damage the product Do not use any source of high pressure washe...

Page 5: ...DCOCT21_V2 ML Accessories Limited LU5 4LT www mlaccessories co uk 02 INTERNATIONAL CONTACT DETAILS INTERNAT CONTACT D 20 C 45 C TA ...

Reviews: