INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following product:
4IPB / 4IPW
SAFETY
•
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•
Please isolate mains prior to installation or maintenance
•
Check the total load on the circuit (including when this product
is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
•
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
•
This product should be installed in the upright position
•
This product is Class III
•
This product is IP67 rated
INSTALLATION
Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires.
This product requires a 24V DC constant voltage LED driver, fittings must be wired in parallel.
•
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
•
The power source connections should be local and accessible via a suitable IP rated enclosure
•
Cut a suitable hole in the mounting surface as per the cut-out details (see Fig.1) ensuring not to
infringe with any joists, gas/water pipes or electrical cables
Fig. 1
•
We recommend not installing in areas where there is a high risk of flooding or areas where water may
sit on top of the fitting (see Fig. 2)
Fig. 2
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following product:
4IPB / 4IPW
SAFETY
•
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•
Please isolate mains prior to installation or maintenance
•
Check the total load on the circuit (including when this product
is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
•
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
•
This product should be installed in the upright position
•
This product is Class III
•
This product is IP67 rated
INSTALLATION
Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires.
This product requires a 24V DC constant voltage LED driver, fittings must be wired in parallel.
•
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
•
The power source connections should be local and accessible via a suitable IP rated enclosure
•
Cut a suitable hole in the mounting surface as per the cut-out details (see Fig.1) ensuring not to
infringe with any joists, gas/water pipes or electrical cables
Fig. 1
•
We recommend not installing in areas where there is a high risk of flooding or areas where water may
sit on top of the fitting (see Fig. 2)
Fig. 2
• We recommend not installing in areas where there is a high risk of flooding or areas where water may sit on
top of the fitting (see Fig. 2)
Fig. 1
Fig. 2