MKS SG 1024 Technical Notes Download Page 18

page   16  of  16                                                                                                            File: SG1024_r1eng - April 2017 - Technical note: SG 1024

PM 250 

             

SG 1024 S

olid

 S

tate

 M

icrowave

 G

enerator

How to order

Solid State Microwave Generator

SG1024E.yyyjb,

 where:

yyy

:  

contact yr mks representative upon  

 

selection of the custom unit;

j

 (version code): 

vers. 0:

 n.a.

 

vers. 1: 

“Fieldbus” 

 

vers. 2: 

“Display” & manual commands 

b

 (fieldbus type): 

MTCP: 

Modbus-TCP

 

PLNK:  

Powerlink

 
I.e.:

SG 1024E.MKS2 means generator Display version;
SG 1024E.MKS1MTCP means generator version with Modbus-TCP bus 
interface

Accessories

Plug set: 

   

p/n 

44SET524

(contains plugs for Conn #1 and #5 only)

Coax Plug, right angle, 7/16 M-F:  p/n 

MWCOAX7/16L

Coax cable, length 1 m, 1/2”: 

p/n 

441384810/1M0

Coax cable, length 1 m, 7/8”: 

p/n 

441384811/1M0

Cable set for input line and signals only: p/n 

441384524

Waveguide to coax transition,

WR340 to 7/16, flange R26: 

p/n 

MWR26-COAX7/16L

WR284 to 7/16, flange R32: 

p/n 

MWR32-COAX7/16L

 

Quick-lock water connector:  

p/n 

PNCBI061810

 

 

(Staubli type: CBI 061810/IA/JV/CN)

MKS Alter reserves the right to improve or modify this products, at any 
time, without obligation to notify any person or entity of such changes.
No part of this publication may be reproduced without the express writ-
ten consent of MKS

All rights reserved.

Technical Assistance:

 

MKS Alter Italy 

42122 Reggio Emilia - ITALY

Tel: ++39 0522 553 820;  fax ++39 

0522 553 577

Web: www.altersystem.com

Summary of Contents for SG 1024

Page 1: ...SOLID STATE MICROWAVE GENERATOR 1000 W 2450 MHZ TECHNICAL NOTE issue April 2017 SG 1024...

Page 2: ...Cover Rear...

Page 3: ...tati membri relative alla compatibilit elettromagnetica Conformity to the Directives is assured through the application of the following standards La conformit alle Direttve assicurata tramite l appli...

Page 4: ...ies products covered by the Directive as a matter of fact it does not perform a function alone must be included into a larger process equipment and it s for stationary use Nevertheless we invite the U...

Page 5: ...Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement With reference to Basic Standard EN55011 this equipment is...

Page 6: ...e The SG 1024 is offered in two versions the Display version with front panel manual commands and PLC interface to control by I O it carries also one USB standard port which allows to drive read data...

Page 7: ...ency 26 Output power range Wrf 50 1000 Adjustable range 2 100 Max value differs at frequency band limit Output linearity Wrf 20 Forward power Displayed value vs monitor signal Output stability 1 For i...

Page 8: ...uction for any doubt then power on the unit through your external contactor Once switched OFF wait at least two seconds before setting it ON again The OFF state between two consecutive ON state must l...

Page 9: ...Troubleshooting table at page 15 for the complete alarm list and relative codes Note the last alarm occured is permanently stored by the CPU even in absence of main line and can be verified using the...

Page 10: ...be set in external mode using a signal AUTOMATIC TUNING is a feature of the unit based on a patented algorithm US patent 6 020 794 Due to the possibility to change the operating frequency the user can...

Page 11: ...pages The number enclosed in brackets refers to the small number associated to names of pages in the previous layout 0 1 At POWER ON the unit shows the Logo its name and software version for a moment...

Page 12: ...power and parts of the circuit on the final power combiner as well as the coaxial socket may be damaged 6 INFO this page shows the last alarm that occured the software version the generator is runnin...

Page 13: ...4810 1 Preferred size other length on request max 2 m Coax Cable 7 8 with 7 16 Plugs l 1m 441384811 1 Other length on request max 4 m 3 Transition 7 16 to WR340 MWR26 COAX7 16L Aluminum construction F...

Page 14: ...nitor signals in the range 0 10Vdc pin 2 and pin 3 ground on pin 15 and 16 respectively Forward and Reverse Power Monitor CONN 2 LOCATION Forward Power Wrf 1 Vmon 100 W TBD Pin no 2 return on pin 15 R...

Page 15: ...m section or ask our Application Note for the protocol implemented Each SG 1024 generator must be associated to an address the two digital rotating switches must be used the left switch sets the tens...

Page 16: ...nector MOCPC03 2060362 6 1 CPU Board 800000536 B 7 1 DC Power Supply Board 800000538 8 1 Display Board 800000537 9 1 Fan VE8414NGH 10 1 Line breaker with lever IGM22061192003M1 11 1 Lever 12 1 Solid s...

Page 17: ...Input Malfunction PLL Alarm linked to internal frequency generator the generated driving signal is out of expected value The CPU turns off the power module automatically After the reset operation the...

Page 18: ...x Plug right angle 7 16 M F p n MWCOAX7 16L Coax cable length 1 m 1 2 p n 441384810 1M0 Coax cable length 1 m 7 8 p n 441384811 1M0 Cable set for input line and signals only p n 441384524 Waveguide to...

Reviews: