5.

 

Technical Specifications 

 
Power supply Vin 

 

 

 

12 - 30 Vdc 

 

Power 

consumption 

  : 

 

50 mA (no-load operation) 

 

Aux. encoder supply output   

 

5.2 volts and Vin – 2 volts,  2x 125 mA  

(short-circuit-proof) 

 

Max. 

frequency   : 

 

400 kHz (RS422), 200 kHz (HTL) 

 

Inputs 

    : 

 

Single-ended A, B, Z (2x), 10 – 30 volts or 
differential A, /A, B, /B, Z, /Z (2x), 2 – 30 volts 

 

Outputs 

 

 

 

Push-pull A, /A, B, /B, Z, /Z (2x) 

Level 5 – 30 volts, 30 mA (short-circuit-proof) 

 

Signal propagation delay 

 

approx. 600 nsec. 

 

Ambient 

temperature 

  : 

 

Operation: 0° - 45° (32 - 113 °F) 
Storage:  -25° - +70° (-13  -  158 °F) 

 

Weight    : ca. 

100 

 

Conformity and standards   

 
 

EMC 89/336/EEC: 

EN 61000-6-2 

   EN 

61000-6-3 

LV73/23/EEC:  

EN 61010-1 

 

Summary of Contents for GV 210

Page 1: ...A B B Z Z A A B B Z Z A A B B Z Z A A B B Z Z Universal encoder interface applicable as level converter encoder splitter and encoder cross switch Two encoder inputs A B Z and A B Z adjustable to eith...

Page 2: ...this unit is used with applications where failure or maloperation could cause damage to a machine or hazard to the operating staff it is indispensable to meet effective precautions in order to avoid s...

Page 3: ...1 Dual level converter 4 1 2 Encoder splitter dual output 4 1 3 Encoder signal switcher 5 2 Connection Diagram 6 2 1 Power supply 6 2 2 Control inputs 6 2 3 Encoder inputs 6 2 4 Outputs 7 3 The Front...

Page 4: ...put 1 LOW or unconnected and Control input 2 HIGH the signal ways are as shown in the drawing above featuring two independent level converters 1 2 Encoder splitter dual output In1 Control 1 LOW n c Co...

Page 5: ...ven when no inverted signals are applied to the input Inputs Control1 and Control2 select the signal ways LOW The corresponding output is connected to input 1 HIGH The corresponding output is connecte...

Page 6: ...2 position power terminal on the front side terminal 1 terminal 2 GND The current consumption is about 50 mA aux voltages and outputs unloaded 1 5 Control inputs The control inputs are accessible via...

Page 7: ...the switching threshold lies between 6 5 and 8 volts The input uses an internal pull down resistor of 5kOhms Every of the two input terminals provides two auxiliary voltage outputs for easy encoder su...

Page 8: ...nd the basic function of the unit Yellow LED off Control1 and Control2 are either both LOW or both HIGH at the same time In this case the unit operates as a splitter both outputs are connected to the...

Page 9: ...volts 0 Z 0 B 0 A Input 2 differential A A B B Z Z Both input and inverted input must be available Levels from 2 to 30 volts are acceptable 1 Z 1 B 1 A Input 2 single ended A B Z with HTL level Invert...

Page 10: ...GV21001e_e_A5 doc Jul 07 Page 10 11 4 Dimensions 102 4 016 91 3 583 82 5 3 248 102 4 016 22 5 0 886 1 2 3 4 5 6 7 8 OFF ON Side view Top view Front view...

Page 11: ...Max frequency 400 kHz RS422 200 kHz HTL Inputs Single ended A B Z 2x 10 30 volts or differential A A B B Z Z 2x 2 30 volts Outputs Push pull A A B B Z Z 2x Level 5 30 volts 30 mA short circuit proof...

Reviews: