Connecting the unit
40
Installation instructions
6.7 Making the exhaust air connection
When setting up the unit under a ventilation system, observe the
regional regulations for heating, ventilation and air conditioning
systems.
ATTENTION
Risk of physical damage from fouling of the exhaust air
ducts
•
Do not connect the exhaust air line directly to the ventilation
system.
ATTENTION
Risk of corrosion damage from condensate
•
Install the exhaust air line such that condensate cannot
collect.
6.7.1 Connecting the exhaust air line
Image: Connecting the exhaust air line
Requirement
Exhaust air line complies with the specifications (see "Equipment and
connection data")
1. Connect the exhaust air line to the steam outlet.
2. Route the exhaust air line with a 3° rise as far as the ventilation
system.
3. Fasten the end of the exhaust air line 50 mm — 200 mm
underneath the ventilation system.
4. Fill out the Commissioning report.