70
EN
power light isn’t on
Fuse damaged
Change it
Input power damaged
Change it
2
After welding machine is
over-heat, the fan doesn’t
work
Fan damaged
Change it
The cable is loose
Screw the cable tight
3
Press the
gun
switch, no
output
shielded
gas
No output
gas when
test gas
No gas in the gas cylinder
Change it
Gas hose leaks gas
Change it
Electromagneticvalve
damaged
Change it
Output gas
when test
gas
Control switch damaged
Repair the switch
Control circuit damaged
Check the PCB
4
Wire-
feeder
doesn’t
work
Wire reel
doesn’t
work
Motor damaged
Check and change it
Control circuit damaged
Check the PCB
Wire reel
works
The press wheel is loosen or
weld wire skids
Press it tightly again
The wheel doesn’t fit with
the diameter of weld wire
Change the wheel
Wire reel damaged
Change it
Wire feed pipe is jammed
Repair or change it
Tip is jammed because of
splash
Repair or change it
5
No striking arc and no
output voltage
Output cable is connected
incorrectly or loosen
Screw it down or change it
Control circuit damaged
Check the circuit
6
Welding stops, and alarm
light is on
Machine has self-protection
Check over-voltage, over-current,
over-temperature, lower-voltage
and over-temperature, and solve it
7
Welding current is run
away and can be not
controlled
The potentiometer damaged Check or change it
The
control
circuit
damaged
Check the circuit
8
The crater current can be
not adjusted
The PCB damaged
Check it
9
No post-gas
The PCB damaged
Check it
Summary of Contents for Multi-GMAW 200 LCD PFC
Page 24: ...23 DE 12 WIG Stecker Belegung EIN AUS 10K Poti zum Reglen des Schwei stromes Stecker Belegung...
Page 25: ...24 DE 13 Spool GUN Stecker Belegung EIN AUS Taster Strom Regler Stecker Belegung...
Page 29: ...28 DE 17 Schematischer Schaltplan Multi GMAW 250 LCD PFC 230V...