MK-100 TRACKER
Revision 02/03, Effective Date February 12, 2003
Page 38
MAINTENANCE AND TROUBLESHOOTING
°
7. Blade Stops Turning:
* A GFCI wall socket is the preferred protective device.
(D)
Verify the circuit breaker is at
least 20 amps – if not, move to
20-amp circuit
(A)
Allow motor to cool and
depress motor Overload
Reset Switch
(F)
Check power source voltage is
115V, if it is not 115v – move
to another circuit
(B)
Verify all plugs are fully
Installed*
(C)
Check to see if the Ground
Fault Circuit Interrupter (GFCI)
is tripped*
(E)
Verify circuit breaker is not
tripped, if it is tripped – reset the
circuit breaker once
Return to
MK Diamond
for Repair
(G)
Return to MK Diamond
If less than 20
Amps move saw
to 20 Amp circuit
Overload
Reset Switch
If motor does not
start, go to Step B
Verify all plugs
connected
If all plugs connected,
go to Step C
If not tripped, or
If a re-trip occurs,
Go to Step D
Reset once
if tripped
If circuit 20 Amp
or greater
go to Step E
Check Breaker
20 Amps
or greater
If tripped, reset
once if trips again,
go to step F
If circuit breaker
not tripped
go to Step F
Check Breaker
tripped
Check for
correct circuit
voltage
If voltage is
115V -
go to Step G