CHAPTER 6
ELECTRICAL SYSTEM
- 26 -
34z
Check that AC VOLTS are now reading on the AC digital meter.
Turn the breakers ON for items you wish to operate.
Note: if the generator starts, but no AC voltage is detected at the panel, check first that the
selector switches (sliding interlocks) at the top of the AC panel are configured correctly. If this
does not solve the problem, there is a possibility the generator was overloaded and the AC
breaker on the generator itself has tripped due to a momentary overload. Open the generator
hatch and reset the AC Output Circuit Breaker (located on the control box, where the wires are
connected).
STOP: Depress STOP switch until the generator stops completely
BOW
STERN
AC Output Breaker
Switch
Operating Instructions