background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAFETY WARNING 

1. Warning   

  Every person involved with the installation , operation and maintenance of this 

device has to be qualified . 

  User must follow the instructions of this manual   

  Unqualified person can not open the housing cover and operate the device , or the 

dealer will not accept liability for any resulting defects or problems.   

  The device against rain and moisture   

 

2. Waring notes :   

  Power supply : AC 100V-240V , 50/60Hz   

  Make sure the power switch is off , the power plug , outlet and the earth connection 

is in well condition before connecting the device with the mains.   

  Please use qualified power plug and the outlet. Never connect the power cord of 

this device with other electrical equipment.   

  During move and installation , make sure the device not crashed with metal parts 

and other tough materials.   

  Always disconnect from the  mains, when the device is on the installation and 

dismantled 

  The minimum distance between light-output and the illuminated surface must be 

more than 50cm   

  The device must only be installed on a non-flammable surface . In order to 

safeguard sufficient ventilation , leave 50cm of free space around the device . Please 

note that heat-sensitive objects may be    deformed or damaged by the emitted heat .   

  During the operation the housing becomes very hot ! Do not operate the device for 

15 minutes after switching off .   

  The maximum ambient temperature Ta = 45

  must never be exceeded , The 

maximum housing temperature Tb = 80

  must never be exceeded .   

  For indoor use   

  Replace any visible cracked protective shield , filters and lens .   

  The protective shiel, filters and lens will require weekly cleaning as smoke “Cfluid 

tends to building up residues , reducing the light “Coutput very quickly. 

9

 

 

1. Product Introduction

 

1.1

 Product Feature

 

4 control mode   

 

External control mode   

 

DMX512 controller controller mode 

2 kind of DMX Channel

 

 

Master/slave 

 

Auto mode 

 

Built-in Program 

 

Different kind of Gradual change& Random change   

 

Different kind of strobe

speed (slow to fast)

fix color( color

 

Gradual change)…… 

 

Setting Program 

 

It can setting the program without the controller , it can setting Gradual 

change

jump change

strobe ...(different effect)   

 

And the program data can be down load from master light to slave light 

 

Static model 

 

It can fix the color without the controller ,also can be choose the color with 

strobe 

 

Sound model 

 

Included 2 kinds of commonly used sound model 

 

  “Software cutting ” 

  In the STAR mode , working built-in program /setting program ,the light would be 

turn off when the dimmer channel as "0"

procedure would keep working) 

  The difference with “BLACKOUT” key(controller keys) &"Software cutting" 

only 

work this light , and do not clear up the controller data . 

 

White color   

  Setting different color temperature of white color     

 

Screen Protection 

  Without operate key in 30 seconds , it enter black screen. Press any

 keys then 

it 

can quit screen protection.     

 

Temperature Protection

 

  It can set to protect the temperature . 

                       2

 

 

Summary of Contents for MJ-3337C-200W

Page 1: ...C 200W User Manual PROFESSIONAL LED LIGHTING Thank you for choosing our LED profile light with zoom For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Page 2: ... quality optical system Glass reflector Beam Angel Zoom from 15 to 28 or 20 to 45 High quality optical system Glass reflector Control Mode DMX Auto run and Master Slave DMX Channels 4 8CH Cooling System Low noise fan one fan IP Rating IP20 N W 10 kgs G W 13kgs Dimensions 800x305x310mm 1 APPENDIX Caution Unqualified person involved with installation operation and maintenance of this device is prohi...

Page 3: ...mperature Ta 45 must never be exceeded The maximum housing temperature Tb 80 must never be exceeded For indoor use Replace any visible cracked protective shield filters and lens The protective shiel filters and lens will require weekly cleaning as smoke Cfluid tends to building up residues reducing the light Coutput very quickly 9 1 Product Introduction 1 1 Product Feature 4 control mode External ...

Page 4: ...gree and the speed will get the faster as the temperature get high Can be showed reverse display 1 2 Multi light working in the same time When using controller to control several lights and using strobe auto mode the controller just send the channel data Those effect strobe auto running fix color would be showed by itself And should be attention for the follow situation 1 There will be many situat...

Page 5: ...he first list is the main menu press MENU to exchange the second list is submenu press ENTER to get in or exchange If the menu include the decimal point that s the data and it can be set by the Key of Up Down Key operation Key of MENU Press it and can save the data If it s the main menu it will exchange to next main menu If it s the submenu it will back to main menu Key of ENTER Press it and can s...

Page 6: ...uto run ENTER Enter vice menu SP speed UP DOWN Adjust the speed select the speed of auto run ENTER Save data None Sod sound UP DOWN change to Sound control Sound mode ENTER Save data 5 With multi vice menus StAt static ENTER Enter vice menu Static model r G b W UP DOW N Change the value of led Led set ENTER Save data and change to vice menu St strobe UP DOW N Change the value of strobe Strobe and ...