2.2 Basic channel model   

Channel 

Data 

Function 

Mark 

CH1 

0~255 

Dimmer 

 

CH2 

0~255 

Color 1 (R) 

 

CH3 

0~255 

Color 2 (G) 

 

CH4 

0~255 

Color 3 (B) 

 

CH5 

0~255 

Color 4 (W) 

 

CH6 

0~30 

No effect 

 

31~200 

Multi color change 

201~205 

Color temperature 1 (3200k) 

`````` 

Color temperature 2~10 (each 5 

data is a color temperature) 

250~255 

Color temperature 11 (10000k) 

CH7 

0~10 

No strobe 

this channel 

control the speed 

when running the 

build-in  program  

11~255 

The speed of strobe from slow to 

fast 

CH8 

0~20 

speed of dimmer 4 (the slowest 

and softest) 

 

21~40 

speed of dimmer 3 

 

41~60 

speed of dimmer 2 

 

61~80 

speed of dimmer 1 

 

81~99 

speed of dimmer OFF (fastest 

and no any delay) 

100~109 

inner program 1 

 

`````` 

each 10 data is a program 

 

190~199 

inner program 10 

 

200~240 

change color by sound control 

 

241~255 

strobe by sound control 

 

 

                              

  4

 

3. Operation 

MENU

Switch the main menu

 

UP/DOWN

Change the value of the current menu item

 

ENTER

If there are sub menu switch submenu 

 

MEUN 

SUB MRUN 

DISPLAY 

KEY OPERATION 

Standard 
channel model

8 channel

 

 

DMX(8CH) 
Addr:001 

UP/DOWN change the address code 

Simple channel 
model 

4channel

 

 

DMX(4CH) 
Addr:001 

UP/DOWN change the address code 

Static mode

 

Dimmer

 

Color1

Red

 

Static > 
R   :000 

UP/DOWN : dimmer 
ENTER : switch sub menu 

Dimmer

 

Color2 (Green) 

Static > 
G   :000 

UP/DOWN :dimmer 
ENTER :switch sub menu 

Dimmer

 

Color3 (Blue) 

Static > 
B   :000 

UP/DOWN :dimmer 
ENTER :switch sub menu 

Dimmer

 

Color4 (White) 

Static > 
W   :000 

UP/DOWN :dimmer 
ENTER :switch sub menu 

Strobe 

Static > 
Strob:00 

UP/DOWN :strobe 
ENTER :switch sub menu 

Temperature 
control

 

Display the 
current 
temperature 

Temp   > 
Curr:  0 

ENTER :switch sub menu 

Setting the 
temperature 
protection 

Temp   > 
Top :080 

UP/DOWN :temperature value 
ENTER :switch sub menu 

RESET TO 
DEFAULT

 

 

Reset 
 

After press ENTER, prompted for a 
password, as follows

   

 

Reset 
Pwd: 

Press the UP/DOWN key to enter the 
password, input a password will 
display a "*". As follows: 

 

Reset 
Pwd:**** 

Press ENTER to confirm password. 
Password correct will reset to default. 
Otherwise will remove all the "*", in 
order to enter the password again

 

 

Note:

1) If the first line of menu shows”>” , it means there has  sub menu can change by 

“ENTER” 

     2) The password is“UP

DOWN

UP

DOWN”. 

5

 

 

 

Summary of Contents for MJ-3325C-200W26D

Page 1: ...200W26D User Manual PROFESSIONAL LED LIGHTING Thank you for choosing our LED profile spot light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Page 2: ...o program freely to any different lighting project requirements for installation or showing This high power par can has gotten the nice sculpt efficient save electricity and durable Technical Parameter Power Supply AC90V 260V 50 60Hz Power Consumption Max 260W LED 200W RGBW 4in1 LED Color LED Life time over 50 000 hours Small volume lightweight High quality optical system Beam Angel 26 High qualit...

Page 3: ... white light It can be set 11 kinds of white light with different color temperature and controlled by the controller Screen Protect It will enter blank screen without any operate on the keyboard in 30 seconds Press any keys then it can quit screen protection Temperature Protection It can be set to temperature protection mode 2 APPENDIX Caution Unqualified person involved with installation operatio...

Page 4: ... must never be exceeded The maximum housing temperature Tb 80 must never be exceeded For indoor use Replace any visible cracked protective shield filters and lens The protective shiel filters and lens will require weekly cleaning as smoke Cfluid tends to building up residues reducing the light Coutput very quickly 6 Speed of the Fan The fan will start to work when the working temperature reach 40 ...

Page 5: ...ON Standard channel model 8 channel DMX 8CH Addr 001 UP DOWN change the address code Simple channel model 4channel DMX 4CH Addr 001 UP DOWN change the address code Static mode Dimmer Color1 Red Static R 000 UP DOWN dimmer ENTER switch sub menu Dimmer Color2 Green Static G 000 UP DOWN dimmer ENTER switch sub menu Dimmer Color3 Blue Static B 000 UP DOWN dimmer ENTER switch sub menu Dimmer Color4 Whi...