background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAFETY WARNING 

1. Warning   

  Every person involved with the installation , operation and maintenance of this device has 

to be qualified . 

  User must follow the instructions of this manual   

  Unqualified person can not open the housing cover and operate the device , or the dealer 

will not accept liability for any resulting defects or problems.   

  The device against rain and moisture   

 

2. Waring notes :   

  Power supply : AC 100V-240V , 50/60Hz   

  Make sure the power switch is off , the power plug , outlet and the earth connection is in 

well condition before connecting the device with the mains.   

  Please use qualified power plug and the outlet. Never connect the power cord of this 

device with other electrical equipment.   

  During move and installation , make sure the device not crashed with metal parts and other 

tough materials.   

  Always disconnect from the mains, when the device is on the installation and dismantled 

  The minimum distance between light-output and the illuminated surface must be more than 

50cm   

  The device must only be installed on a non-flammable surface . In order to safeguard 

sufficient ventilation , leave 50cm of free space around the device . Please note that 

heat-sensitive objects may be    deformed or damaged by the emitted heat .   

  During the operation the housing becomes very hot ! Do not operate the device for 15 

minutes after switching off .   

  The maximum ambient temperature Ta = 45

  must never be exceeded , The maximum 

housing temperature Tb = 80

 must never be exceeded .   

  For indoor use   

  Replace any visible cracked protective shield , filters and lens .   

  The protective shiel, filters and lens will require weekly cleaning as smoke “Cfluid tends 

to building up residues , reducing the light “Coutput very quickly.   

 

                              

  6

 

 

 

Speed of the Fan 

 

The fan will start to work when the working temperature reach 40 degree, and the 

speed will be changed according to the change of temperature. 

 

Can support reverse display 

 
1.2 Multi-light working in the same time 

When using controller to control multi lights to work in strobe or auto run, the controller just 

send the channel data . The strobe and auto run effect will be depend on each light itself . And 

please take attention for the follow situation:

 

 

1.

 

There will be many situations make the lights are not synchronization in the beginning. 

(For example: the different time of opening the light , or different time of them connect to the 

controller) .In this case,    you can change value of the controller( for example push 20 to 0, and 

back to 20), then it can be synchronization. 

2.

 

Due to crystal frequency of different lights are not the same exactly, so it may not be 

synchronization after long time. 

3.

 

If need to keep synchronization for long time, there are two ways to do so: 

       A. Using the controller to edit program make the strobe, auto run effect, then they must 

be synchronization. 

       B. Using the Maser/Slave model 

 

2. Channel data

 

2.1 Standard channel model 

Channel 

Data 

Function 

CH1 

0~255 

Red 

CH2 

0~255 

Green 

CH3 

0~255 

Blue 

CH4 

0~255 

White 

 

                              

  3 

Summary of Contents for MJ-3325C-200W26D

Page 1: ...200W26D User Manual PROFESSIONAL LED LIGHTING Thank you for choosing our LED profile spot light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Page 2: ...o program freely to any different lighting project requirements for installation or showing This high power par can has gotten the nice sculpt efficient save electricity and durable Technical Parameter Power Supply AC90V 260V 50 60Hz Power Consumption Max 260W LED 200W RGBW 4in1 LED Color LED Life time over 50 000 hours Small volume lightweight High quality optical system Beam Angel 26 High qualit...

Page 3: ... white light It can be set 11 kinds of white light with different color temperature and controlled by the controller Screen Protect It will enter blank screen without any operate on the keyboard in 30 seconds Press any keys then it can quit screen protection Temperature Protection It can be set to temperature protection mode 2 APPENDIX Caution Unqualified person involved with installation operatio...

Page 4: ... must never be exceeded The maximum housing temperature Tb 80 must never be exceeded For indoor use Replace any visible cracked protective shield filters and lens The protective shiel filters and lens will require weekly cleaning as smoke Cfluid tends to building up residues reducing the light Coutput very quickly 6 Speed of the Fan The fan will start to work when the working temperature reach 40 ...

Page 5: ...ON Standard channel model 8 channel DMX 8CH Addr 001 UP DOWN change the address code Simple channel model 4channel DMX 4CH Addr 001 UP DOWN change the address code Static mode Dimmer Color1 Red Static R 000 UP DOWN dimmer ENTER switch sub menu Dimmer Color2 Green Static G 000 UP DOWN dimmer ENTER switch sub menu Dimmer Color3 Blue Static B 000 UP DOWN dimmer ENTER switch sub menu Dimmer Color4 Whi...

Reviews: