Safety Instructions

•  Read all safety instructions before using the Wi-Fi Adaptor.

•  This installation manual contains important safety information. Be sure to 

comply with the instructions.

•  After installing the Wi-Fi Adaptor, provide this installation manual to the 

user. Instruct users to store it with their heat pump instruction manual in 

a safe location.

Warning

(Improper handling may have serious consequences, including serious injury or death.)

• Installation of the adaptor must be carried 

out by an authorised installer only.

• Improper installation may result in fire, 

electric shock, or damage/water leaks. 

Consult the dealer from whom you 

purchased the unit, or a professional 

installer.

• The adaptor should be securely  

installed in accordance with this 

installation manual.

• The unit should be mounted in a location 

that can support its weight.

• If the unit is installed in a location that 

cannot support its weight, the Wi-Fi 

Adaptor could fall and cause damage.

• Connect and fasten the electric wires 

securely so external force on the wires will 

not apply on the terminals.

• Improper connection and mounting may 

result in breakdown, heat generation, 

smoke generation, or fire.

• Mitsubishi Electric components or other 

designated components must be used for 

installation.

• Improper components may result in fire, 

electric shock, or damage/water leaks. 

• Electrical work must be performed 

by a licensed professional using the 

instructions detailed in the installation 

manual.

• Inadequate circuit capacity or improper 

installation may result in electric shock 

or fire.

• This appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, 

or lack of experience and knowledge, 

unless they have been given supervision 

or instruction concerning use of the 

appliance by a person responsible for 

their safety.

• Children should be supervised to ensure 

that they do not play with the appliances.

• This device complies with all Australia 

and New Zealand requirements for EMC 

and electrical safety.

• Do not connect the Wi-Fi Adaptor to earth 

inside the heat pump.

Summary of Contents for Wi-Fi Control

Page 1: ...1 INSTALLATION GUIDE...

Page 2: ...ommissioning Date MAC 559IF E Installation Date Installer Contact Details Name Telephone Number Wi Fi Control Minimum Requirements for Operation Compatible WPS router capable of WPA2 AES encryption Th...

Page 3: ...Heat Pump Control Register Your Heat Pump s Thank you for choosing a Mitsubishi Electric Heat Pump with Wi Fi Control Once your adaptor is installed either download the app search term Mitsubishi Ele...

Page 4: ...abled Router Wi Fi Installation Guide Tools to remove cover of indoor unit 2 Phillips Important Note Before going to the users home ensure they have a WPS capable router and WPA2 AES encryption can be...

Page 5: ...le to be connected to the user s router Steps for this are shown on the following pages 6 5 7 8 Remove the cover of the indoor unit the cable terminal and the cover to the control board Locate the CN1...

Page 6: ...r to your router manual for more information Activate WPS mode on your router This will be enabled for a set period allowing approximately two minutes to complete Step 3 To do so please refer to your...

Page 7: ...h alternately the unit is successfully connected to the internet If LED 2 orange lights up at any stage there may be a problem Check the troubleshooting section on page 11 You can now download the Mit...

Page 8: ...and cause damage Connect and fasten the electric wires securely so external force on the wires will not apply on the terminals Improper connection and mounting may result in breakdown heat generation...

Page 9: ...for detailed instructions for accessing the control adaptor connector CN105 on the indoor unit control PCB Note Please ensure that the access point supports both WPS connection and the WPA2 AES encryp...

Page 10: ...val once every 5 sec Server communication or access point communication failed and heat pump communication starting up 0 5 sec interval Server communication or access point communication failed and he...

Page 11: ...access point Specifications Input voltage DC12 7V from indoor unit Power consumption MAX 2W Size W H D mm 89 48 6 19 2 Weight 105g including cable RF channel 1ch 13ch Radio protocol IEEE 802 11b g n...

Page 12: ...liament Street PO Box 30772 Lower Hutt 5040 Phone 0800 639 434 Fax 04 560 9133 Helpline Opening Hours 8 30am 5 00pm weekdays Mitsubishi Electric Australia www mitsubishielectric com au wifi SYDNEY HEA...

Reviews: