26
-
'12 • SRK-T-122
'09•SRK-DB-087D
(6)
ޓ
3D auto operation
(a)
1)
2)
(b)
At cooling
Air flow selection
Operation mode
AUTO
HI
MED
LO
Indoor temp. – Setting temp. >5°C
Indoor temp. – Setting temp. 5°C
HIGH POWER
AUTO
HI
MED
LO
<
=
Flap
Louver
Cooling
Up/down Swing
Wide (Fixed)
Flap
Louver
Cooling
Left/right Swing
Horizontal blowing (Fixed)
Flap
Louver
Cooling
Up/down Swing
Center (Fixed)
Wide (Fixed)
Flap
Louver
Cooling
Horizontal blowing (Fixed)
Operation mode
Indoor temp. – Setting temp. 2°C
At cooling
Air flow direction contorol
2°C < Indoor temp. – Setting temp. 5°C
Indoor temp. – Setting temp. > 5°C
The control in d) continues.
Control returns to the control in b).
Control returns to the control in a).
<
=
<
=
Wide (Fixed)
Flap
Air flow selection
Louver
According to DRY operation.
Horizontal blowing (Fixed)
a)
b)
c)
d)
e)
c
d