8 INSPECTION AND MAINTENANCE
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
134
Pub. No. K29001-00320 Revision: 1
Inspection and Maintenance -
Prepare (with Engine Switched OFF)
1
Operate the stop switch of the
generator
Devices Installed during
Manufacturing the Generator" (
2
Make sure with the thermometer
(thermo gun, etc.) that the surface of
the engine is cooled down so that
you can touch.
3
Conduct lockout/tagout.
Engine Body - Check
• Devices and equipment outside the
scope of our supply are included in the
facility. For the details, refer to such a
document as the specification sheet
prepared by the generator supplier.
• For the devices and equipment outside
the scope of our supply, refer the
corresponding manual of the generator
and the supplier's operation manual.
Belt - Check
Check each belt for the crankshaft pulley or
alternator in the engine.
Be sure to lockout/tagout before
starting inspection and maintenance
work.
* Unexpected startup of the engine could cause
serious personal injury or damage to the
devices.
Be sure to establish zero energy state
before starting inspection and
maintenance work.
* Unexpected activation of the devices could
cause serious personal injury or damage to the
devices.
Stay away from rotating parts during
operation.
* Otherwise you may get caught in the rotating
parts and seriously injured.
Keep the belt for the crankshaft
pulley or alternator free from oil and
grease.
* Otherwise, a slip could occur, which will shorten
the service life of the belt.
Check each belt status (tension,
damage and the like) of the
crankshaft pulley or alternator.
* If the belt has been stretched, the battery
cannot be cahrged and DC power supply will be
lost.